Location estimate

Boksburg

Gauteng · South Africa

Approximate location reference—not a rooftop, property or survey point.

Seasonal average-day estimates

Selected capacity 1 kWp

Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.

Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.

Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.

Summer

6.26

kWh/day

Autumn

5.78

kWh/day

Winter

4.82

kWh/day

Spring

7.01

kWh/day

Shared scale: 0–8.00 kWh/day.

I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.

This is illustrative scaling, not a site-specific production prediction.

Source basis and scaling limits

Original seasonal average-day estimates for Boksburg, in kWh/kWp/day.

I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.

Original source values and selected-capacity calculation
SeasonRecorded kWh/kWp/dayExact selected-capacity result · kWh/day
Summer 6.26 6.26 × 1 kWp = 6.26 kWh/day
Autumn 5.78 5.78 × 1 kWp = 5.78 kWh/day
Winter 4.82 4.82 × 1 kWp = 4.82 kWh/day
Spring 7.01 7.01 × 1 kWp = 7.01 kWh/day

Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.

Full results rounded to two decimal places

These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.

Summer · kWh/day
6.26
Autumn · kWh/day
5.78
Winter · kWh/day
4.82
Spring · kWh/day
7.01

The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.

These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Year-round panel setup

Schematic catalogue setting — Year-round fixed panel setup: tilt 25 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Year-round fixed panel setup · schematic
Tilt from horizontal
25°
Facing direction
North

Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.

Suggested seasonal tilts

Tilt from horizontal · facing direction

Summer
Dec, Jan, Feb
10°North
Autumn
Mar, Apr, May
32°North
Winter
Jun, Jul, Aug
42°North
Spring
Sep, Oct, Nov
20°North

The seasonal electricity figures do not model gains from switching between these settings.

About this orientation

This schematic shows the year-round panel tilt and facing direction for Boksburg, Gauteng, South Africa.

For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.

I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.

The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.

Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.

Seasonal orientation diagrams

These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.

Summer

Schematic catalogue setting — Summer panel setup: tilt 10 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Summer panel setup · schematic

10° tilt · North

Illustrative direction; exact azimuth not recorded.

Autumn

Schematic catalogue setting — Autumn panel setup: tilt 32 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Autumn panel setup · schematic

32° tilt · North

Illustrative direction; exact azimuth not recorded.

Winter

Schematic catalogue setting — Winter panel setup: tilt 42 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Winter panel setup · schematic

42° tilt · North

Illustrative direction; exact azimuth not recorded.

Spring

Schematic catalogue setting — Spring panel setup: tilt 20 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Spring panel setup · schematic

20° tilt · North

Illustrative direction; exact azimuth not recorded.

Historical hourly-by-season solar output chart for Boksburg, South Africa. View larger
Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

Hourly electricity pattern for Boksburg, South Africa

Hourly profiles by season — Boksburg, South Africa · 2021

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

2021 is the method’s reference year, not verified year coverage for every point in this historical chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.

Historical hourly chart

Hourly profiles by season — Boksburg, South Africa · 2021

Swipe to pan, or focus the chart and use arrow keys.

Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern.

2021 is the method’s reference year, not verified year coverage for every plotted point.

Enlargement is limited to the original image resolution.

Row-spacing planning

Planning solar-panel row spacing in Boksburg

Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.

Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.

Row pitch including margin

≈ 2.81 m

Proportional side viewDesign sun: ≈ 40.33° above horizontal
Row 1 Row 2 Clear gap Added margin: 0 m Row pitch including margin
  • Sunlight ray
  • First row’s ground shadow
  • Shadow endpoint
Calculated clear gap
≈ 1 m
Added margin
≈ 0 m
Gap including margin
≈ 1 m
Panel horizontal footprint
≈ 1.81 m
Panel vertical rise
≈ 0.85 m
Pitch before margin
≈ 2.81 m

Simplified level ground, equator-facing cross-section. Approximate Southern Hemisphere winter solstice at solar noon (day 172). The separate recorded facing direction is not an input.

One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.

Detailed inputs and unrounded results

More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.

Panel surface length
2 m
Tilt up from horizontal
25°
Added margin
0 m
Latitude from the catalogue
-26.219800000000000000° (Southern Hemisphere)
Panel horizontal footprint
1.8126155740732999 m
Panel vertical rise
0.8452365234813989 m
Calculated clear gap
0.9955967442059852 m
Pitch before margin
2.808212318279285 m
Gap including margin
0.9955967442059852 m
Row pitch including margin
2.808212318279285 m
Design solar elevation
40.33041715318635°
How this spacing estimate is calculated

I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.

δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).

Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.

The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.

The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.

Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Solar context for Boksburg

Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.

Boksburg's solar reference has its highest seasonal value in spring. Our estimated average daily electricity per 1 kW of rated panel capacity is 7.01 kWh/day in spring, 6.26 kWh/day in summer, 5.78 kWh/day in autumn and 4.82 kWh/day in winter. The comparison is between seasonal averages: it should not be read as the amount produced on every day of the year.

Read the full article

We record a fixed-panel year-round reference of 25° from horizontal, facing North. That is a broad output-weighted setting using simplified solar geometry. It offers a useful comparison for this Southern Hemisphere location, while the orientation and pitch of an existing roof may constrain the layout that is practical on a particular building. Boksburg forms part of Ekurhuleni's elevated inland landscape. The metropolitan area contains ridges, koppies, rivers and pans as well as extensive development. For a solar installation, the immediate surroundings can therefore matter even where a neighbourhood appears gently rolling: a nearby rise, tree line or building may interrupt the horizon seen from a roof. Wind affects structural loading, while cloud changes the sunlight reaching the panels; they are different issues. Roof condition and mounting design should be checked against the actual exposure rather than assuming that a strong-looking frame resolves all weather-related risks. Water routes around roof outlets and electrical equipment are similarly specific to the building. The seasonal figures help us compare likely generation timing with a project's electricity use. They do not establish the condition of the mounting surface or the performance of a complete system, so those details belong in the next stage of a Boksburg project assessment.

Topography around Boksburg

These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.

Boksburg sits within Ekurhuleni's high inland terrain. The city's spatial framework describes metropolitan elevations of roughly 1,480–1,800 metres above sea level, with ridges and koppies extending through parts of the urban area towards Boksburg and neighbouring centres. That regional range describes the wider landscape, not a surveyed height for this catalogue point.

Read the full topography description

The relief is more varied than a simple flat-plain description suggests. Developed areas lie among rolling ground, local ridges and drainage features; the municipal framework also distinguishes rivers and pans as important parts of the landscape. Some prominent raised features in the metropolitan area are mine dumps or tailings structures, so an elevated skyline is not always a natural ridge. This gives a practical local focus for solar planning: examine the skyline from the proposed panel position, rather than inferring an unobstructed view from a regional map. A broad roof can still have obstructions at its edges or nearby, and open land can have drainage or previous-use constraints that are not apparent from its surface shape. The topography provides context for that inspection. It does not turn a roof or field into a verified installation site, but it helps explain why two nearby Boksburg properties can differ in exposure and layout despite sharing the same regional solar reference.

Technical location reference

Approximate map point used for Boksburg, South Africa

This coordinate is the calculation reference for Boksburg, South Africa. Extra decimal places do not make it a rooftop, property or survey point.

Coordinates and precision
Map coordinate
-26.219800000000000000, 28.251000000000000000
Originally displayed coordinate
lat-26.2198 / long28.251

How the estimate works

How this Boksburg estimate was calculated

Here is how I calculated the location estimate for Boksburg, South Africa.

Read how all Location estimates work

Source and scope

I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.

The figures are calculated estimates, not measured output or a new NASA request while you browse.

Reference period and source details

The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.

NASA POWER project reference

The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.

This source reference does not imply NASA endorsement.

Use the result carefully

What this Boksburg Location estimate includes and leaves out

Use the Boksburg figures for broad location context, with the following boundaries in mind.

  • These catalogue estimates are informational; they do not establish a site-specific production result.
  • The location is an approximate reference, not a property, rooftop or survey coordinate.
  • The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
  • The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
  • Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.

Keep exploring

Compare Boksburg with another location

Back to country results

Detailed site analysis

Take it a step further

Whether you’re exploring solar for your own project or comparing options for your clients, profileSOLAR helps you assess historical generation, compare system configurations and produce clear reports.

Detailed analysis for your project or your clients.

Explore features and paid access in the app, or use the complimentary testing access included in your invitation.

Analysis features and access

The profileSOLAR app supports hourly solar analysis over periods of up to five consecutive years, subject to available source data. No electricity-use file is required for this solar analysis.

Compare supported panel configurations, then download Summary or Detailed PDF reports for the saved Analysis.

Testing access includes only the features and allowances stated in your invitation. Your catalogue selection is not transferred; choose your exact site in the app.

Explore detailed site analysis