Location estimate
Caledon
Western Cape · South Africa
Approximate location reference—not a rooftop, property or survey point.
Seasonal average-day estimates
Selected capacity 1 kWp
Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.
Logarithmic slider: each labelled interval is 10× capacity. Energy scales linearly with capacity.
Arrow keys change capacity by about 2.3 percent per step. Page Up and Page Down move one labelled interval. Home selects 0.1 kWp; End selects 10 MWp.
Enter exact capacity and unit
Enter at least 0.1 kWp. Decimal point or comma; no thousands separators. 1 MWp = 1,000 kWp. Changing units keeps the same capacity. Exact entry keeps your precision; slider adjustments select three-significant-figure sizes.
There is no fixed upper capacity limit. Values and results must fit the calculator’s numeric range; the slider’s range is not an exact-entry limit.
Showing seasonal average-day estimates for 1 kWp.
Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.
Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.
Summer
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Autumn
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Winter
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Spring
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Very large results use scientific notation; an approximate capacity label is marked ≈. Exact capacity and full results remain available under Source basis and scaling limits.
Shared scale: 0–8.00 kWh/day.
I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.
This is illustrative scaling, not a site-specific production prediction.
Source basis and scaling limits
Original seasonal average-day estimates for Caledon, in kWh/kWp/day.
I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.
| Season | Recorded kWh/kWp/day | Exact selected-capacity result · kWh/day |
|---|---|---|
| Summer | 7.91 | 7.91 × 1 kWp = 7.91 kWh/day |
| Autumn | 4.42 | 4.42 × 1 kWp = 4.42 kWh/day |
| Winter | 3.33 | 3.33 × 1 kWp = 3.33 kWh/day |
| Spring | 6.64 | 6.64 × 1 kWp = 6.64 kWh/day |
Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.
Full results rounded to two decimal places
These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.
- Summer · kWh/day
- 7.91
- Autumn · kWh/day
- 4.42
- Winter · kWh/day
- 3.33
- Spring · kWh/day
- 6.64
The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.
These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.
Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.
Year-round panel setup
- Tilt from horizontal
- 30°
- Facing direction
- North
Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.
Suggested seasonal tilts
Tilt from horizontal · facing direction
- Summer
Dec, Jan, Feb - 18°North
- Autumn
Mar, Apr, May - 39°North
- Winter
Jun, Jul, Aug - 49°North
- Spring
Sep, Oct, Nov - 27°North
The seasonal electricity figures do not model gains from switching between these settings.
About this orientation
This schematic shows the year-round panel tilt and facing direction for Caledon, Western Cape, South Africa.
For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.
I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.
The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.
Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.
Seasonal orientation diagrams
These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.
Summer
18° tilt · North
Illustrative direction; exact azimuth not recorded.
Autumn
39° tilt · North
Illustrative direction; exact azimuth not recorded.
Winter
49° tilt · North
Illustrative direction; exact azimuth not recorded.
Spring
27° tilt · North
Illustrative direction; exact azimuth not recorded.
View larger
Hourly electricity pattern for Caledon, South Africa
Hourly profiles by season — Caledon, South Africa · 2021
This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.
2021 is the method’s reference year, not verified year coverage for every point in this historical chart.
The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.
Row-spacing planning
Planning solar-panel row spacing in Caledon
Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.
Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.
Panel and spacing inputs
Along the tilted surface, across the row. Greater than 0, up to 20 m; 2 m is an example.
Optional extra space, 0–100 m.
Starts at the recorded year-round tilt. Decimal entry is kept at your entered precision.
Linear slider: arrows select the next whole degree; Page Up/Down 10°, Home 0°, End 90°. Only moving it changes your numeric entry.
Results update automatically.
Example calculated with a 2 m panel surface length. Replace that example with the dimension of the module you are considering.
Example calculated with a 2 m panel surface length. Replace that example with the dimension of the module you are considering. Other published location estimates remain available.
Adjust the inputs to update this diagram and its results.
Row pitch including margin
≈ m
- Sunlight ray
- First row’s ground shadow
- Shadow endpoint
At this scale the panel surfaces are very small. The row labels locate them; exact dimensions remain available below.
- Calculated clear gap
- ≈ m
- Added margin
- ≈ 0 m
- Gap including margin
- ≈ m
- Panel horizontal footprint
- ≈ m
- Panel vertical rise
- ≈ m
- Pitch before margin
- ≈ m
Simplified level ground, equator-facing cross-section. Approximate Southern Hemisphere winter solstice at solar noon (day 172). The separate recorded facing direction is not an input.
One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.
Detailed inputs and unrounded results
More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.
- Panel surface length
- 2 m
- Tilt up from horizontal
- 30°
- Added margin
- 0 m
- Latitude from the catalogue
- -34.219100000000000000° (Southern Hemisphere)
- Panel horizontal footprint
- 1.7320508075688774 m
- Panel vertical rise
- 0.9999999999999999 m
- Calculated clear gap
- 1.579943162886431 m
- Pitch before margin
- 3.3119939704553083 m
- Gap including margin
- 1.579943162886431 m
- Row pitch including margin
- 3.3119939704553083 m
- Design solar elevation
- 32.331117153186355°
How this spacing estimate is calculated
I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.
δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).
Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.
The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.
The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.
Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.
Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.
Solar context for Caledon
Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.
Caledon’s recorded solar estimates at 34.2191° S, 19.4252° E favour summer and spring, while retaining a smaller winter contribution. Average daily electrical output per kW of rated installed PV capacity is 7.91 kWh/day in summer, 4.42 in autumn, 3.33 in winter and 6.64 in spring. Summer is about 2.4 times winter. This is a substantial seasonal contrast for any building or business operating throughout the year.
Read the full article
Spring extends the stronger generation period beyond midsummer, whereas autumn sits much nearer the winter estimate. Electricity demand should be compared with that pattern. Daytime activity during the brighter months may coincide with abundant generation, but a winter load cannot be assessed using summer yield alone. The figures are seasonal electrical averages, rather than daily minimums or a judgement about one property’s economic return. The recorded fixed-panel reference is 30° from horizontal, facing North. It is a simplified, output-weighted solar-geometry orientation for year-round use. The roof’s pitch, direction and obstruction profile can require a different arrangement. The four seasonal estimates do not quantify a production gain from changing tilt, and a north-facing slope is not automatically an unshaded one. Caledon’s foothill position beneath the Klein Swartberg makes the local skyline important. The town developed around springs on the mountain slopes, and the Baths River runs through the settlement. Buildings on lower ground can have a different view of the northern sky from those on more open slopes. A broad Overberg landscape description cannot substitute for checking the ridge and trees visible from the intended array. The river and its tributaries also give the town a drainage structure. The municipal spatial account identifies associated wetlands and floodplain ground, as well as remaining fynbos and renosterveld areas. These features are substantive parts of Caledon’s landscape. A field that has already been cleared for farming cannot be assumed to have low ecological or agricultural value, nor can its drainage be labelled manageable without examining it. For an existing roof, the useful next considerations are the supporting structure, nearby obstacles and safe maintenance access. For a ground array, slope, water movement and the access route need to be considered together. Mounting design and material selection should suit actual exposure and applicable loads. Summer hail, frequent morning fog, universal salt deposition and a fixed cleaning schedule are not established by these estimates. Caledon’s seasonal resource can be used without assuming one weather risk or one engineering condition across its varied foothill setting.
Topography around Caledon
These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.
Caledon sits at the foot of the Klein Swartberg in the Overberg, beside the N2 transport corridor. The immediate setting combines mountain slopes, developed foothill ground and lower land associated with the Baths River. This is a more useful local description than a broad elevated plateau: changes in slope and proximity to the mountain can matter over the distance between neighbouring parts of town.
Read the full topography description
The Baths River is a prominent linear feature through Caledon. Together with its tributaries, wetlands and floodplain areas, it forms a connected water landscape across parts of the town and commonage. The river and railway have also influenced the division and development of the settlement. An array’s relationship to these features depends on the actual building or plot, rather than the general direction in which the wider region falls towards the coast. The municipality’s spatial analysis identifies steep slopes north and west of the town. It also records intact Overberg Sandstone Fynbos on the Klein Swartberg and patches of Western Rûens Shale Renosterveld within the urban edge. Agricultural land is another important component of the surroundings. These are distinct land-cover and terrain settings, not interchangeable open areas for energy development. For sunlight, a foothill roof needs to be assessed against the particular ridge sector that interrupts its sky. A higher position can improve a view in one direction while bringing an array closer to an obstruction in another. Trees, buildings and the lower winter sun add local differences. The reference north-facing panel direction therefore needs an actual skyline assessment. For ground-mounted panels, slope length and the position of drainage lines influence both row layout and runoff. A track or levelled platform can redirect water travelling downhill, while a low crossing may affect access during wet conditions. Vegetation cover helps hold the surface and slows runoff. The existence of a natural channel does not demonstrate that drainage will remain uncomplicated after construction. Nearby roads and the railway provide geographic context, but they do not establish a project’s access rights or electrical connection capacity. Similarly, a large wheat or grazing field cannot be assumed to be spare land simply because the surface is relatively open. Caledon’s useful topographic assessment stays with its mountain–foothill–river relationships, preserving the distinction between a clear solar horizon and a parcel whose ground, water and existing uses support the proposed layout.
Technical location reference
Approximate map point used for Caledon, South Africa
This coordinate is the calculation reference for Caledon, South Africa. Extra decimal places do not make it a rooftop, property or survey point.
Coordinates and precision
- Map coordinate
- -34.219100000000000000, 19.425200000000000000
- Originally displayed coordinate
- lat-34.2191 / long19.4252
How the estimate works
How this Caledon estimate was calculated
Here is how I calculated the location estimate for Caledon, South Africa.
Read how all Location estimates workSource and scope
I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.
The figures are calculated estimates, not measured output or a new NASA request while you browse.
Reference period and source details
The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.
NASA POWER project reference
The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.
This source reference does not imply NASA endorsement.
Use the result carefully
What this Caledon Location estimate includes and leaves out
Use the Caledon figures for broad location context, with the following boundaries in mind.
- These catalogue estimates are informational; they do not establish a site-specific production result.
- The location is an approximate reference, not a property, rooftop or survey coordinate.
- The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
- The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
- Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.