Location estimate

Guro-gu

Seoul · South Korea

Approximate location reference—not a rooftop, property or survey point.

Seasonal average-day estimates

Selected capacity 1 kWp

Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.

Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.

Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.

Summer

5.53

kWh/day

Autumn

3.73

kWh/day

Winter

2.95

kWh/day

Spring

5.35

kWh/day

Shared scale: 0–6.00 kWh/day.

I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.

This is illustrative scaling, not a site-specific production prediction.

Source basis and scaling limits

Original seasonal average-day estimates for Guro-gu, in kWh/kWp/day.

I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.

Original source values and selected-capacity calculation
SeasonRecorded kWh/kWp/dayExact selected-capacity result · kWh/day
Summer 5.53 5.53 × 1 kWp = 5.53 kWh/day
Autumn 3.73 3.73 × 1 kWp = 3.73 kWh/day
Winter 2.95 2.95 × 1 kWp = 2.95 kWh/day
Spring 5.35 5.35 × 1 kWp = 5.35 kWh/day

Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.

Full results rounded to two decimal places

These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.

Summer · kWh/day
5.53
Autumn · kWh/day
3.73
Winter · kWh/day
2.95
Spring · kWh/day
5.35

The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.

These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Year-round panel setup

Schematic catalogue setting — Year-round fixed panel setup: tilt 34 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Year-round fixed panel setup · schematic
Tilt from horizontal
34°
Facing direction
South

Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.

Suggested seasonal tilts

Tilt from horizontal · facing direction

Summer
Jun, Jul, Aug
21°South
Autumn
Sep, Oct, Nov
42°South
Winter
Dec, Jan, Feb
52°South
Spring
Mar, Apr, May
30°South

The seasonal electricity figures do not model gains from switching between these settings.

About this orientation

This schematic shows the year-round panel tilt and facing direction for Guro-gu, Seoul, South Korea.

For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.

I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.

The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.

Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.

Seasonal orientation diagrams

These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.

Summer

Schematic catalogue setting — Summer panel setup: tilt 21 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Summer panel setup · schematic

21° tilt · South

Illustrative direction; exact azimuth not recorded.

Autumn

Schematic catalogue setting — Autumn panel setup: tilt 42 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Autumn panel setup · schematic

42° tilt · South

Illustrative direction; exact azimuth not recorded.

Winter

Schematic catalogue setting — Winter panel setup: tilt 52 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Winter panel setup · schematic

52° tilt · South

Illustrative direction; exact azimuth not recorded.

Spring

Schematic catalogue setting — Spring panel setup: tilt 30 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Spring panel setup · schematic

30° tilt · South

Illustrative direction; exact azimuth not recorded.

Historical hourly-by-season solar output chart for Guro-gu, South Korea. View larger
Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

Hourly electricity pattern for Guro-gu, South Korea

Hourly profiles by season — Guro-gu, South Korea · 2021

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

2021 is the method’s reference year, not verified year coverage for every point in this historical chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.

Historical hourly chart

Hourly profiles by season — Guro-gu, South Korea · 2021

Swipe to pan, or focus the chart and use arrow keys.

Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern.

2021 is the method’s reference year, not verified year coverage for every plotted point.

Enlargement is limited to the original image resolution.

Row-spacing planning

Planning solar-panel row spacing in Guro-gu

Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.

Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.

Row pitch including margin

≈ 3.67 m

Proportional side viewDesign sun: ≈ 29.07° above horizontal
Row 1 Row 2 Clear gap Added margin: 0 m Row pitch including margin
  • Sunlight ray
  • First row’s ground shadow
  • Shadow endpoint
Calculated clear gap
≈ 2.01 m
Added margin
≈ 0 m
Gap including margin
≈ 2.01 m
Panel horizontal footprint
≈ 1.66 m
Panel vertical rise
≈ 1.12 m
Pitch before margin
≈ 3.67 m

Simplified level ground, equator-facing cross-section. Approximate Northern Hemisphere winter solstice at solar noon (day 355). The separate recorded facing direction is not an input.

One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.

Detailed inputs and unrounded results

More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.

Panel surface length
2 m
Tilt up from horizontal
34°
Added margin
0 m
Latitude from the catalogue
37.478400000000000000° (Northern Hemisphere)
Panel horizontal footprint
1.6580751451100835 m
Panel vertical rise
1.1183858069414936 m
Calculated clear gap
2.0116706228502834 m
Pitch before margin
3.669745767960367 m
Gap including margin
2.0116706228502834 m
Row pitch including margin
3.669745767960367 m
Design solar elevation
29.071817153186355°
How this spacing estimate is calculated

I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.

δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).

Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.

The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.

The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.

Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Solar context for Guro-gu

Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.

<h3>Solar Energy Potential in Guro-gu, South Korea</h3>

Read the full article

Guro-gu, a district in Seoul, South Korea, located at latitude 37.4784 and longitude 126.8982, offers varying potential for solar energy generation throughout the year. This location in the Northern Temperate Zone experiences distinct seasonal changes, which significantly impact solar energy production. The estimated daily electricity yield for this record fluctuates with the seasons. Summer proves to be the most productive period, with an average daily output of 5.53 kWh per kilowatt of installed solar capacity. Spring follows closely behind, generating 5.35 kWh/day. These seasons offer the best conditions for solar energy production due to longer daylight hours and more direct sunlight. Autumn sees a noticeable decrease in solar output, with 3.73 kWh/day. Winter presents the greatest challenge for solar energy generation, producing only 2.95 kWh/day. This reduction is primarily due to shorter days, lower sun angles, and potentially increased cloud cover. For those considering installing solar panels in Guro-gu, it's crucial to optimize the panel setup. The ideal tilt angle for fixed solar panels at this location is 34 degrees facing south. This angle maximizes year-round energy production by capturing the most sunlight possible across all seasons. <h3>Environmental Factors and Mitigation Strategies</h3> While Guro-gu's location is generally favorable for solar energy, there are some environmental factors to consider: 1. Air pollution: Seoul, including Guro-gu, can experience high levels of air pollution, particularly fine dust. This can reduce solar panel efficiency by blocking sunlight. 2. Seasonal weather patterns: Monsoon season (typically June to August) can bring heavy rainfall and increased cloud cover, potentially affecting summer production. To mitigate these issues, consider the following preventative measures: <ul> <li>Install self-cleaning panels or implement regular cleaning schedules to combat dust and pollution buildup.</li> <li>Use high-efficiency panels that perform well in low-light conditions to maximize output during cloudy periods.</li> <li>Consider a solar tracking system to adjust panel angles throughout the day, increasing overall energy capture.</li> </ul> By addressing these factors and optimizing panel installation, Guro-gu residents can make the most of their solar energy systems year-round, despite seasonal variations in output.

Topography around Guro-gu

These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.

Guro-gu, located in the southwestern part of Seoul, South Korea, is situated in a predominantly urban landscape with a mix of topographical features. The area is characterized by a combination of low-lying flatlands and gently rolling hills, typical of the Seoul Basin region. The western and southern portions of Guro-gu are relatively flat, with elevations generally ranging from 10 to 30 meters above sea level. This area is part of the broader Han River floodplain, which has been extensively developed for residential and industrial purposes. The eastern and northern parts of Guro-gu gradually rise in elevation, with some small hills reaching heights of 50 to 100 meters. To the west of Guro-gu lies the Anyang Stream, a tributary of the Han River, which flows northward through the neighboring district of Geumcheon-gu. This waterway creates a natural boundary and contributes to the overall flatness of the western areas. <h3>Potential for Large-scale Solar PV</h3> When considering areas nearby that would be most suited for large-scale solar photovoltaic (PV) installations, several factors come into play, including available land, sunlight exposure, and proximity to existing infrastructure. The flatlands to the west and southwest of Guro-gu, extending into parts of Bucheon and Gwangmyeong cities, offer potential for solar PV development. These areas have fewer tall buildings and natural obstacles that could cast shadows, allowing for maximum sunlight exposure throughout the day. However, it's important to note that much of this land is already developed or designated for other uses. Another promising area for solar PV installations could be the gently sloping hillsides to the east and southeast of Guro-gu, extending into parts of Gwanak-gu and Dongjak-gu. These elevated areas may receive more consistent sunlight and could potentially accommodate larger installations without interfering with existing urban development. It's worth noting that while these areas show potential for solar PV development, the dense urban nature of the Seoul metropolitan area presents challenges for large-scale installations. Any significant solar projects would likely need to be integrated into existing structures or developed on repurposed industrial land. Rooftop solar installations on large commercial and industrial buildings throughout Guro-gu and neighboring districts may offer a more practical solution for harnessing solar energy in this highly urbanized region.

Technical location reference

Approximate map point used for Guro-gu, South Korea

This coordinate is the calculation reference for Guro-gu, South Korea. Extra decimal places do not make it a rooftop, property or survey point.

Coordinates and precision
Map coordinate
37.478400000000000000, 126.898200000000000000
Originally displayed coordinate
lat37.4784 / long126.8982

How the estimate works

How this Guro-gu estimate was calculated

Here is how I calculated the location estimate for Guro-gu, South Korea.

Read how all Location estimates work

Source and scope

I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.

The figures are calculated estimates, not measured output or a new NASA request while you browse.

Reference period and source details

The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.

NASA POWER project reference

The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.

This source reference does not imply NASA endorsement.

Use the result carefully

What this Guro-gu Location estimate includes and leaves out

Use the Guro-gu figures for broad location context, with the following boundaries in mind.

  • These catalogue estimates are informational; they do not establish a site-specific production result.
  • The location is an approximate reference, not a property, rooftop or survey coordinate.
  • The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
  • The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
  • Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.

Keep exploring

Compare Guro-gu with another location

Back to catalogue

Detailed site analysis

Take it a step further

Whether you’re exploring solar for your own project or comparing options for your clients, profileSOLAR helps you assess historical generation, compare system configurations and produce clear reports.

Detailed analysis for your project or your clients.

Explore features and paid access in the app, or use the complimentary testing access included in your invitation.

Analysis features and access

The profileSOLAR app supports hourly solar analysis over periods of up to five consecutive years, subject to available source data. No electricity-use file is required for this solar analysis.

Compare supported panel configurations, then download Summary or Detailed PDF reports for the saved Analysis.

Testing access includes only the features and allowances stated in your invitation. Your catalogue selection is not transferred; choose your exact site in the app.

Explore detailed site analysis