Location estimate

Khartoum North

Khartoum · Sudan

Approximate location reference—not a rooftop, property or survey point.

Seasonal average-day estimates

Selected capacity 1 kWp

Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.

Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.

Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.

Summer

7.17

kWh/day

Autumn

6.84

kWh/day

Winter

6.45

kWh/day

Spring

8.00

kWh/day

Shared scale: 0–8.00 kWh/day.

I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.

This is illustrative scaling, not a site-specific production prediction.

Source basis and scaling limits

Original seasonal average-day estimates for Khartoum North, in kWh/kWp/day.

I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.

Original source values and selected-capacity calculation
SeasonRecorded kWh/kWp/dayExact selected-capacity result · kWh/day
Summer 7.17 7.17 × 1 kWp = 7.17 kWh/day
Autumn 6.84 6.84 × 1 kWp = 6.84 kWh/day
Winter 6.45 6.45 × 1 kWp = 6.45 kWh/day
Spring 8.00 8.00 × 1 kWp = 8.00 kWh/day

Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.

Full results rounded to two decimal places

These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.

Summer · kWh/day
7.17
Autumn · kWh/day
6.84
Winter · kWh/day
6.45
Spring · kWh/day
8.00

The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.

These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Year-round panel setup

Schematic catalogue setting — Year-round fixed panel setup: tilt 15 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Year-round fixed panel setup · schematic
Tilt from horizontal
15°
Facing direction
South

Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.

Suggested seasonal tilts

Tilt from horizontal · facing direction

Summer
Jun, Jul, Aug
0°No facing direction needed
Autumn
Sep, Oct, Nov
22°South
Winter
Dec, Jan, Feb
31°South
Spring
Mar, Apr, May
9°South

The seasonal electricity figures do not model gains from switching between these settings.

About this orientation

This schematic shows the year-round panel tilt and facing direction for Khartoum North, Khartoum, Sudan.

For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.

I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.

The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.

Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.

Seasonal orientation diagrams

These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.

Summer

A 0° setting is flat; no compass-facing direction applies.

Summer panel setup

0° tilt · No facing direction needed

Flat panel: facing direction has no practical effect.

Autumn

Schematic catalogue setting — Autumn panel setup: tilt 22 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Autumn panel setup · schematic

22° tilt · South

Illustrative direction; exact azimuth not recorded.

Winter

Schematic catalogue setting — Winter panel setup: tilt 31 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Winter panel setup · schematic

31° tilt · South

Illustrative direction; exact azimuth not recorded.

Spring

Schematic catalogue setting — Spring panel setup: tilt 9 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Spring panel setup · schematic

9° tilt · South

Illustrative direction; exact azimuth not recorded.

Historical hourly-by-season solar output chart for Khartoum North, Sudan. View larger
Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

Hourly electricity pattern for Khartoum North, Sudan

Hourly profiles by season — Khartoum North, Sudan · 2021

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

2021 is the method’s reference year, not verified year coverage for every point in this historical chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.

Historical hourly chart

Hourly profiles by season — Khartoum North, Sudan · 2021

Swipe to pan, or focus the chart and use arrow keys.

Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern.

2021 is the method’s reference year, not verified year coverage for every plotted point.

Enlargement is limited to the original image resolution.

Row-spacing planning

Planning solar-panel row spacing in Khartoum North

Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.

Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.

Row pitch including margin

≈ 2.35 m

Proportional side viewDesign sun: ≈ 50.9° above horizontal
Row 1 Row 2 Clear gap Added margin: 0 m Row pitch including margin
  • Sunlight ray
  • First row’s ground shadow
  • Shadow endpoint
Calculated clear gap
≈ 0.42 m
Added margin
≈ 0 m
Gap including margin
≈ 0.42 m
Panel horizontal footprint
≈ 1.93 m
Panel vertical rise
≈ 0.52 m
Pitch before margin
≈ 2.35 m

Simplified level ground, equator-facing cross-section. Approximate Northern Hemisphere winter solstice at solar noon (day 355). The separate recorded facing direction is not an input.

One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.

Detailed inputs and unrounded results

More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.

Panel surface length
2 m
Tilt up from horizontal
15°
Added margin
0 m
Latitude from the catalogue
15.648300000000000000° (Northern Hemisphere)
Panel horizontal footprint
1.9318516525781366 m
Panel vertical rise
0.5176380902050415 m
Calculated clear gap
0.42064430584975654 m
Pitch before margin
2.3524959584278933 m
Gap including margin
0.42064430584975654 m
Row pitch including margin
2.3524959584278933 m
Design solar elevation
50.90191715318635°
How this spacing estimate is calculated

I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.

δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).

Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.

The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.

The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.

Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Solar context for Khartoum North

Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.

Khartoum North, also known as Bahri, forms one part of the metropolitan landscape around the meeting of the Blue and White Niles. Its urban roofs and river-side ground provide different immediate settings for solar, even within the broadly low-relief area.

Read the full article

Spring has the largest estimated daily average at 8.00 kWh/day per 1 kW of rated panel capacity. Summer averages 7.17 kWh/day, autumn 6.84 kWh/day and winter 6.45 kWh/day. These are seasonal averages of daily energy, not a promise of consistent output or a complete assessment of whether a system can operate reliably at a particular site. The fixed year-round reference is 15° up from horizontal, facing South. It is a broad output-weighted setting based on simplified geometry. A real roof's shape, neighbouring structures and usable area remain relevant when comparing it with that reference. The metropolitan geography is organised by three river branches and their banks. Khartoum North lies on the northern/eastern side of the Blue Nile and main Nile setting, distinct from Khartoum and Omdurman across the waterways. River terraces and more gently varied inland ground form part of the wider state's physical landscape. For a local installation, operating conditions should be examined directly. Heat, deposits, drainage and the condition of the building can affect a practical system, and they should not be dismissed as minor simply because the seasonal resource is strong. The catalogue figures do not establish current infrastructure or access conditions.

Topography around Khartoum North

These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.

Khartoum North belongs to the three-part metropolitan area defined by the Blue Nile, White Nile and the main Nile below their confluence. The waterways separate its setting from Khartoum and Omdurman and give river banks and terraces an important role in the urban landscape.

Read the full topography description

The wider Khartoum State terrain includes low-relief river terraces and gently varying ground along these channels. At a smaller scale, the relative height of a property, the river margin and local drains can matter even where distant views suggest a broadly flat plain. Built areas and river-side land also differ in their immediate surroundings. A roof enclosed by neighbouring structures has a different horizon from open ground closer to a river or farther inland. General openness does not quantify shade at a particular array. For any ground-based proposal, a specific site's drainage, existing use and relation to the river need to be examined. Describing the wider landscape as arid cannot establish that northern or eastern land has little ecological or agricultural value. This is a physical account of the locality, not a current survey of land availability, infrastructure condition or access. It does not select a development sector or model river-related hazards for an individual property.

Technical location reference

Approximate map point used for Khartoum North, Sudan

This coordinate is the calculation reference for Khartoum North, Sudan. Extra decimal places do not make it a rooftop, property or survey point.

Coordinates and precision
Map coordinate
15.648300000000000000, 32.524500000000000000
Originally displayed coordinate
lat15.6483 / long32.5245

How the estimate works

How this Khartoum North estimate was calculated

Here is how I calculated the location estimate for Khartoum North, Sudan.

Read how all Location estimates work

Source and scope

I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.

The figures are calculated estimates, not measured output or a new NASA request while you browse.

Reference period and source details

The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.

NASA POWER project reference

The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.

This source reference does not imply NASA endorsement.

Use the result carefully

What this Khartoum North Location estimate includes and leaves out

Use the Khartoum North figures for broad location context, with the following boundaries in mind.

  • These catalogue estimates are informational; they do not establish a site-specific production result.
  • The location is an approximate reference, not a property, rooftop or survey coordinate.
  • The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
  • The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
  • Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.

Keep exploring

Compare Khartoum North with another location

Back to country results

Detailed site analysis

Take it a step further

Whether you’re exploring solar for your own project or comparing options for your clients, profileSOLAR helps you assess historical generation, compare system configurations and produce clear reports.

Detailed analysis for your project or your clients.

Explore features and paid access in the app, or use the complimentary testing access included in your invitation.

Analysis features and access

The profileSOLAR app supports hourly solar analysis over periods of up to five consecutive years, subject to available source data. No electricity-use file is required for this solar analysis.

Compare supported panel configurations, then download Summary or Detailed PDF reports for the saved Analysis.

Testing access includes only the features and allowances stated in your invitation. Your catalogue selection is not transferred; choose your exact site in the app.

Explore detailed site analysis