Location estimate

Jacksonville Beach

Florida · United States

Approximate location reference—not a rooftop, property or survey point.

Seasonal average-day estimates

Selected capacity 1 kWp

Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.

Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.

Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.

Summer

5.82

kWh/day

Autumn

4.71

kWh/day

Winter

3.49

kWh/day

Spring

6.43

kWh/day

Shared scale: 0–7.00 kWh/day.

I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.

This is illustrative scaling, not a site-specific production prediction.

Source basis and scaling limits

Original seasonal average-day estimates for Jacksonville Beach, in kWh/kWp/day.

I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.

Original source values and selected-capacity calculation
SeasonRecorded kWh/kWp/dayExact selected-capacity result · kWh/day
Summer 5.82 5.82 × 1 kWp = 5.82 kWh/day
Autumn 4.71 4.71 × 1 kWp = 4.71 kWh/day
Winter 3.49 3.49 × 1 kWp = 3.49 kWh/day
Spring 6.43 6.43 × 1 kWp = 6.43 kWh/day

Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.

Full results rounded to two decimal places

These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.

Summer · kWh/day
5.82
Autumn · kWh/day
4.71
Winter · kWh/day
3.49
Spring · kWh/day
6.43

The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.

These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Year-round panel setup

Schematic catalogue setting — Year-round fixed panel setup: tilt 27 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Year-round fixed panel setup · schematic
Tilt from horizontal
27°
Facing direction
South

Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.

Suggested seasonal tilts

Tilt from horizontal · facing direction

Summer
Jun, Jul, Aug
14°South
Autumn
Sep, Oct, Nov
35°South
Winter
Dec, Jan, Feb
46°South
Spring
Mar, Apr, May
23°South

The seasonal electricity figures do not model gains from switching between these settings.

About this orientation

This schematic shows the year-round panel tilt and facing direction for Jacksonville Beach, Florida, United States.

For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.

I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.

The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.

Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.

Daily tilt. Solar noon is when the Sun crosses the local meridian. Its geometric elevation at transit today is 38.3°. When the Sun is above the horizon, subtract its elevation from 90° to find the tilt from horizontal.

Local time zone: America/New_York.

Time zone boundaries © OpenStreetMap contributors, via Timezone Boundary Builder. Request the lookup free under the ODbL.
Seasonal orientation diagrams

These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.

Summer

Schematic catalogue setting — Summer panel setup: tilt 14 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Summer panel setup · schematic

14° tilt · South

Illustrative direction; exact azimuth not recorded.

Autumn

Schematic catalogue setting — Autumn panel setup: tilt 35 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Autumn panel setup · schematic

35° tilt · South

Illustrative direction; exact azimuth not recorded.

Winter

Schematic catalogue setting — Winter panel setup: tilt 46 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Winter panel setup · schematic

46° tilt · South

Illustrative direction; exact azimuth not recorded.

Spring

Schematic catalogue setting — Spring panel setup: tilt 23 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Spring panel setup · schematic

23° tilt · South

Illustrative direction; exact azimuth not recorded.

Today’s solar panel tilt

Today () in Jacksonville Beach, United States, tilt your solar panels 51.7° from horizontal, facing true south, to point them directly at the Sun at solar noon.

Local solar noon · about 12:14 EST

Historical hourly-by-season solar output chart for Jacksonville Beach, United States. View larger
Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

Hourly electricity pattern for Jacksonville Beach, United States

Hourly profiles by season — Jacksonville Beach, United States · 2021

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

2021 is the method’s reference year, not verified year coverage for every point in this historical chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.

Historical hourly chart

Hourly profiles by season — Jacksonville Beach, United States · 2021

Swipe to pan, or focus the chart and use arrow keys.

Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern.

2021 is the method’s reference year, not verified year coverage for every plotted point.

Enlargement is limited to the original image resolution.

Row-spacing planning

Planning solar-panel row spacing in Jacksonville Beach

Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.

Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.

Row pitch including margin

≈ 3.02 m

Proportional side viewDesign sun: ≈ 36.27° above horizontal
Row 1 Row 2 Clear gap Added margin: 0 m Row pitch including margin
  • Sunlight ray
  • First row’s ground shadow
  • Shadow endpoint
Calculated clear gap
≈ 1.24 m
Added margin
≈ 0 m
Gap including margin
≈ 1.24 m
Panel horizontal footprint
≈ 1.78 m
Panel vertical rise
≈ 0.91 m
Pitch before margin
≈ 3.02 m

Simplified level ground, equator-facing cross-section. Approximate Northern Hemisphere winter solstice at solar noon (day 355). The separate recorded facing direction is not an input.

One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.

Detailed inputs and unrounded results

More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.

Panel surface length
2 m
Tilt up from horizontal
27°
Added margin
0 m
Latitude from the catalogue
30.278100000000000000° (Northern Hemisphere)
Panel horizontal footprint
1.7820130483767358 m
Panel vertical rise
0.9079809994790935 m
Calculated clear gap
1.2373279313605174 m
Pitch before margin
3.0193409797372532 m
Gap including margin
1.2373279313605174 m
Row pitch including margin
3.0193409797372532 m
Design solar elevation
36.27211715318635°
How this spacing estimate is calculated

I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.

δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).

Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.

The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.

The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.

Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Solar context for Jacksonville Beach

Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.

Jacksonville Beach has an estuarine landscape as well as its Atlantic shore. At Cradle Creek Preserve, the city's account describes largely undisturbed land beside the Intracoastal Waterway, with views over the Pablo Creek Estuary. A natural creek connects the preserve's southern edge with the larger waterway, giving this nearby landscape a branching coastal-water structure.

Read the full article

Spring leads the solar model at 6.43 kWh/day per kW of rated capacity. Summer follows at 5.82, autumn at 4.71 and winter at 3.49 kWh/day per kW of rated capacity. Summer reaches about 91% of spring, while winter reaches about 54%. Spring is about 1.84 times winter. The strongest and weakest seasonal daily averages differ by 2.94 kWh/day per kW of rated capacity. The fixed year-round reference is 27° up from horizontal, facing South. It describes a panel plane derived from simplified solar geometry weighted by modelled output. The preserve's trails and elevated boardwalks follow this water-side setting between the Plantation Oaks and Marsh Side neighbourhoods. The estuary provides a specific local example within the wider coastal community. The four solar values show a spring maximum in daily energy per unit of rated capacity. From an actual mounting position, nearby ground, canopy and buildings are assessed by their apparent height and direction through the sun's path. This skyline complements the seasonal model and fixed inclination.

Topography around Jacksonville Beach

These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.

Cradle Creek Preserve illustrates Jacksonville Beach's Intracoastal Waterway side. The municipal account describes largely undisturbed land, elevated boardwalks and a viewing platform overlooking the Pablo Creek Estuary. The natural creek runs along the preserve's southern boundary and connects with the Intracoastal Waterway. The preserve lies between the Plantation Oaks and Marsh Side neighbourhoods, giving this estuarine landscape a specific place within the coastal community. For solar exposure, the actual skyline around the panel position combines nearby ground, vegetation and structures. Their apparent height along the sun's path is considered alongside the fixed South-facing reference and seasonal daily averages.

Technical location reference

Approximate map point used for Jacksonville Beach, United States

This coordinate is the calculation reference for Jacksonville Beach, United States. Extra decimal places do not make it a rooftop, property or survey point.

Coordinates and precision
Map coordinate
30.278100000000000000, -81.421300000000000000
Originally displayed coordinate
lat30.2781 / long-81.4213

How the estimate works

How this Jacksonville Beach estimate was calculated

Here is how I calculated the location estimate for Jacksonville Beach, United States.

Read how all Location estimates work

Source and scope

I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.

The figures are calculated estimates, not measured output or a new NASA request while you browse.

Reference period and source details

The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.

NASA POWER project reference

The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.

This source reference does not imply NASA endorsement.

Use the result carefully

What this Jacksonville Beach Location estimate includes and leaves out

Use the Jacksonville Beach figures for broad location context, with the following boundaries in mind.

  • These catalogue estimates are informational; they do not establish a site-specific production result.
  • The location is an approximate reference, not a property, rooftop or survey coordinate.
  • The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
  • The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
  • Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.

Keep exploring

Compare Jacksonville Beach with another location

Back to country results

Detailed site analysis

Take it a step further

Whether you’re exploring solar for your own project or comparing options for your clients, profileSOLAR helps you assess historical generation, compare system configurations and produce clear reports.

Detailed analysis for your project or your clients.

Explore features and paid access in the app, or use the complimentary testing access included in your invitation.

Analysis features and access

The profileSOLAR app supports hourly solar analysis over periods of up to five consecutive years, subject to available source data. No electricity-use file is required for this solar analysis.

Compare supported panel configurations, then download Summary or Detailed PDF reports for the saved Analysis.

Testing access includes only the features and allowances stated in your invitation. Your catalogue selection is not transferred; choose your exact site in the app.

Explore detailed site analysis