Seasonal average-day estimates

Selected capacity 1 kWp

Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.

Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.

Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.

Summer

7.46

kWh/day

Autumn

3.71

kWh/day

Winter

2.46

kWh/day

Spring

5.82

kWh/day

Shared scale: 0–8.00 kWh/day.

I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.

This is illustrative scaling, not a site-specific production prediction.

Source basis and scaling limits

Original seasonal average-day estimates for Wangoom, in kWh/kWp/day.

I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.

Original source values and selected-capacity calculation
SeasonRecorded kWh/kWp/dayExact selected-capacity result · kWh/day
Summer 7.46 7.46 × 1 kWp = 7.46 kWh/day
Autumn 3.71 3.71 × 1 kWp = 3.71 kWh/day
Winter 2.46 2.46 × 1 kWp = 2.46 kWh/day
Spring 5.82 5.82 × 1 kWp = 5.82 kWh/day

Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.

Full results rounded to two decimal places

These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.

Summer · kWh/day
7.46
Autumn · kWh/day
3.71
Winter · kWh/day
2.46
Spring · kWh/day
5.82

The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.

These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Year-round panel setup

Schematic catalogue setting — Year-round fixed panel setup: tilt 33 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Year-round fixed panel setup · schematic
Tilt from horizontal
33°
Facing direction
North

Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.

Suggested seasonal tilts

Tilt from horizontal · facing direction

Summer
Dec, Jan, Feb
22°North
Autumn
Mar, Apr, May
43°North
Winter
Jun, Jul, Aug
53°North
Spring
Sep, Oct, Nov
31°North

The seasonal electricity figures do not model gains from switching between these settings.

About this orientation

This schematic shows the year-round panel tilt and facing direction for Wangoom, Victoria, Australia.

For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.

I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.

The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.

Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.

Seasonal orientation diagrams

These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.

Summer

Schematic catalogue setting — Summer panel setup: tilt 22 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Summer panel setup · schematic

22° tilt · North

Illustrative direction; exact azimuth not recorded.

Autumn

Schematic catalogue setting — Autumn panel setup: tilt 43 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Autumn panel setup · schematic

43° tilt · North

Illustrative direction; exact azimuth not recorded.

Winter

Schematic catalogue setting — Winter panel setup: tilt 53 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Winter panel setup · schematic

53° tilt · North

Illustrative direction; exact azimuth not recorded.

Spring

Schematic catalogue setting — Spring panel setup: tilt 31 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Spring panel setup · schematic

31° tilt · North

Illustrative direction; exact azimuth not recorded.

Historical hourly-by-season solar output chart for Wangoom, Australia. View larger
Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

Hourly electricity pattern for Wangoom, Australia

Hourly profiles by season — Wangoom, Australia · 2021

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

2021 is the method’s reference year, not verified year coverage for every point in this historical chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.

Historical hourly chart

Hourly profiles by season — Wangoom, Australia · 2021

Swipe to pan, or focus the chart and use arrow keys.

Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern.

2021 is the method’s reference year, not verified year coverage for every plotted point.

Enlargement is limited to the original image resolution.

Row-spacing planning

Planning solar-panel row spacing in Wangoom

Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.

Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.

Row pitch including margin

≈ 3.71 m

Proportional side viewDesign sun: ≈ 28.21° above horizontal
Row 1 Row 2 Clear gap Added margin: 0 m Row pitch including margin
  • Sunlight ray
  • First row’s ground shadow
  • Shadow endpoint
Calculated clear gap
≈ 2.03 m
Added margin
≈ 0 m
Gap including margin
≈ 2.03 m
Panel horizontal footprint
≈ 1.68 m
Panel vertical rise
≈ 1.09 m
Pitch before margin
≈ 3.71 m

Simplified level ground, equator-facing cross-section. Approximate Southern Hemisphere winter solstice at solar noon (day 172). The separate recorded facing direction is not an input.

One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.

Detailed inputs and unrounded results

More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.

Panel surface length
2 m
Tilt up from horizontal
33°
Added margin
0 m
Latitude from the catalogue
-38.341600000000000000° (Southern Hemisphere)
Panel horizontal footprint
1.677341135890848 m
Panel vertical rise
1.089278070030054 m
Calculated clear gap
2.0307615811638504 m
Pitch before margin
3.7081027170546985 m
Gap including margin
2.0307615811638504 m
Row pitch including margin
3.7081027170546985 m
Design solar elevation
28.208617153186353°
How this spacing estimate is calculated

I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.

δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).

Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.

The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.

The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.

Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Solar context for Wangoom

Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.

Wangoom belongs to the rural volcanic landscape inland from Warrnambool. Gently undulating ground, agricultural land and local volcanic features distinguish it from the nearby coastal city. The wider locality includes the Lake Wangoom maar and the Hopkins Falls setting, where native planting has helped restore the visitor area.

Read the full article

Our broad fixed reference for solar panels here is 33° facing North. It is an irradiance-weighted solar-position result intended as a year-round starting point. How a particular array uses that orientation depends on the roof or mounting surface and its actual surroundings. The seasonal figures show why both summer and winter need a place in the assessment. Summer averages 7.46 kWh per day per kW of installed solar capacity; spring averages 5.82, autumn 3.71 and winter 2.46 kWh/day per kW. Spring reaches about 78% of summer, autumn about half, and winter about a third. Summer's daily average is just over three times winter's. We would compare those seasonal averages with the property's electricity use, including how much demand occurs during daylight hours. Across Wangoom's rolling rural setting, trees, farm buildings and nearby rises can create different horizons from one proposed array to another. Assessing those immediate features gives the local detail needed to use the regional production figures well, while keeping the stronger summer and spring contribution in view.

Topography around Wangoom

These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.

Wangoom's rural landscape is part of the volcanic country inland from Warrnambool. Regional landform descriptions identify gently undulating rises in the Garvoc–Wangoom area, with lower flats between rises and local lava ridges. Cultivated ground, grazing land and scattered buildings occupy this varied low-relief setting.

Read the full topography description

Lake Wangoom is a distinctive volcanic feature within the wider locality. The geological account describes a maar crater surrounded by a tuff ring, with a higher ridge on its eastern side. This records a different landform from the surrounding lava rises: a broad volcanic depression enclosed by its rim. The Hopkins Falls area provides another recognisable local landscape. Moyne Shire's account places it in rural Wangoom and describes restoration with local native plants. Together, the falls setting, volcanic depression and surrounding agricultural rises form a varied rural landscape. Its local views are shaped by these modest rises, vegetation and the farmed landscape between them.

Technical location reference

Approximate map point used for Wangoom, Australia

This coordinate is the calculation reference for Wangoom, Australia. Extra decimal places do not make it a rooftop, property or survey point.

Coordinates and precision
Map coordinate
-38.341600000000000000, 142.526600000000000000
Originally displayed coordinate
lat-38.3416 / long142.5266

How the estimate works

How this Wangoom estimate was calculated

Here is how I calculated the location estimate for Wangoom, Australia.

Read how all Location estimates work

Source and scope

I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.

The figures are calculated estimates, not measured output or a new NASA request while you browse.

Reference period and source details

The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.

NASA POWER project reference

The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.

This source reference does not imply NASA endorsement.

Use the result carefully

What this Wangoom Location estimate includes and leaves out

Use the Wangoom figures for broad location context, with the following boundaries in mind.

  • These catalogue estimates are informational; they do not establish a site-specific production result.
  • The location is an approximate reference, not a property, rooftop or survey coordinate.
  • The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
  • The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
  • Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.

Keep exploring

Compare Wangoom with another location

Back to catalogue

Detailed site analysis

Take it a step further

Whether you’re exploring solar for your own project or comparing options for your clients, profileSOLAR helps you assess historical generation, compare system configurations and produce clear reports.

Detailed analysis for your project or your clients.

Explore features and paid access in the app, or use the complimentary testing access included in your invitation.

Analysis features and access

The profileSOLAR app supports hourly solar analysis over periods of up to five consecutive years, subject to available source data. No electricity-use file is required for this solar analysis.

Compare supported panel configurations, then download Summary or Detailed PDF reports for the saved Analysis.

Testing access includes only the features and allowances stated in your invitation. Your catalogue selection is not transferred; choose your exact site in the app.

Explore detailed site analysis