Location estimate

Lille

Hauts-de-France · France

Approximate location reference—not a rooftop, property or survey point.

Seasonal average-day estimates

Selected capacity 1 kWp

Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.

Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.

Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.

Summer

5.40

kWh/day

Autumn

2.55

kWh/day

Winter

1.19

kWh/day

Spring

4.98

kWh/day

Shared scale: 0–6.00 kWh/day.

I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.

This is illustrative scaling, not a site-specific production prediction.

Source basis and scaling limits

Original seasonal average-day estimates for Lille, in kWh/kWp/day.

I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.

Original source values and selected-capacity calculation
SeasonRecorded kWh/kWp/dayExact selected-capacity result · kWh/day
Summer 5.40 5.40 × 1 kWp = 5.40 kWh/day
Autumn 2.55 2.55 × 1 kWp = 2.55 kWh/day
Winter 1.19 1.19 × 1 kWp = 1.19 kWh/day
Spring 4.98 4.98 × 1 kWp = 4.98 kWh/day

Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.

Full results rounded to two decimal places

These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.

Summer · kWh/day
5.40
Autumn · kWh/day
2.55
Winter · kWh/day
1.19
Spring · kWh/day
4.98

The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.

These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Year-round panel setup

Schematic catalogue setting — Year-round fixed panel setup: tilt 43 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Year-round fixed panel setup · schematic
Tilt from horizontal
43°
Facing direction
South

Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.

Suggested seasonal tilts

Tilt from horizontal · facing direction

Summer
Jun, Jul, Aug
34°South
Autumn
Sep, Oct, Nov
53°South
Winter
Dec, Jan, Feb
63°South
Spring
Mar, Apr, May
43°South

The seasonal electricity figures do not model gains from switching between these settings.

About this orientation

This schematic shows the year-round panel tilt and facing direction for Lille, Hauts-de-France, France.

For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.

I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.

The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.

Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.

Seasonal orientation diagrams

These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.

Summer

Schematic catalogue setting — Summer panel setup: tilt 34 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Summer panel setup · schematic

34° tilt · South

Illustrative direction; exact azimuth not recorded.

Autumn

Schematic catalogue setting — Autumn panel setup: tilt 53 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Autumn panel setup · schematic

53° tilt · South

Illustrative direction; exact azimuth not recorded.

Winter

Schematic catalogue setting — Winter panel setup: tilt 63 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Winter panel setup · schematic

63° tilt · South

Illustrative direction; exact azimuth not recorded.

Spring

Schematic catalogue setting — Spring panel setup: tilt 43 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Spring panel setup · schematic

43° tilt · South

Illustrative direction; exact azimuth not recorded.

Historical hourly-by-season solar output chart for Lille, France. View larger
Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

Hourly electricity pattern for Lille, France

Hourly profiles by season — Lille, France · 2021

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

2021 is the method’s reference year, not verified year coverage for every point in this historical chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.

Historical hourly chart

Hourly profiles by season — Lille, France · 2021

Swipe to pan, or focus the chart and use arrow keys.

Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern.

2021 is the method’s reference year, not verified year coverage for every plotted point.

Enlargement is limited to the original image resolution.

Row-spacing planning

Planning solar-panel row spacing in Lille

Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.

Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.

Row pitch including margin

≈ 6.24 m

Proportional side viewDesign sun: ≈ 15.93° above horizontal
Row 1 Row 2 Clear gap Added margin: 0 m Row pitch including margin
  • Sunlight ray
  • First row’s ground shadow
  • Shadow endpoint
Calculated clear gap
≈ 4.78 m
Added margin
≈ 0 m
Gap including margin
≈ 4.78 m
Panel horizontal footprint
≈ 1.46 m
Panel vertical rise
≈ 1.36 m
Pitch before margin
≈ 6.24 m

Simplified level ground, equator-facing cross-section. Approximate Northern Hemisphere winter solstice at solar noon (day 355). The separate recorded facing direction is not an input.

One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.

Detailed inputs and unrounded results

More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.

Panel surface length
2 m
Tilt up from horizontal
43°
Added margin
0 m
Latitude from the catalogue
50.624000000000000000° (Northern Hemisphere)
Panel horizontal footprint
1.462707403238341 m
Panel vertical rise
1.363996720124997 m
Calculated clear gap
4.78004521867743 m
Pitch before margin
6.242752621915772 m
Gap including margin
4.78004521867743 m
Row pitch including margin
6.242752621915772 m
Design solar elevation
15.926217153186348°
How this spacing estimate is calculated

I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.

δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).

Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.

The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.

The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.

Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Solar context for Lille

Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.

Lille's solar setting is an urban one, shaped by its roofscape and the Deûle water corridor. The Citadelle, adjoining green spaces and the Bois-Blancs area illustrate how water, vegetation and development remain connected within the city.

Read the full article

Summer and spring offer the larger estimated average daily electricity figures: 5.40 kWh/day and 4.98 kWh/day respectively for each 1 kW of rated panel capacity. Autumn is 2.55 kWh/day and winter 1.19 kWh/day. These lower seasonal means remain important when considering how generation aligns with electricity use over the year. Our fixed-panel reference is 43° from horizontal, facing South. The setting is an output-weighted estimate using simplified solar geometry. A roof's actual orientation and the position of nearby structures can then be compared with this broad reference. The Deûle provides a useful local focus. Lille's heritage museum traces the city's relationship with water from the Citadelle towards the Rives de la Haute Deûle district. Parks, former defensive works and newer development occupy different parts of this connected landscape, rather than a single expanse of open plain. For an individual building, the usable mounting surface and immediate skyline matter more than a general claim of mild weather. Module-level electronics may help with particular electrical configurations, but cannot restore sunlight blocked by a building or tree. A site-specific layout can examine that relationship while the catalogue supplies the seasonal resource comparison.

Topography around Lille

These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.

Lille lies in a broadly low-relief northern French landscape, but its immediate terrain includes a strongly developed urban surface and a water corridor shaped by the Deûle. Buildings, banks, parks and transport routes add structure within the gentle regional relief.

Read the full topography description

The Citadelle and Bois-Blancs are linked through this water landscape. The city's heritage museum describes a route from the Citadelle to the Rives de la Haute Deûle, following the role water has played in Lille's development. The Citadelle park combines green space with historic fortifications beside the river corridor. These elements give different parts of the city distinct immediate outlooks: mature canopy around parkland differs from closely spaced buildings or a more open developed frontage. They are useful distinctions for understanding a roof's surroundings without treating the city as uniformly clear of obstructions. Solar consideration should begin with the identified roof or ground surface and its existing context. Neither distant coastal cities nor broad Flanders plains establish local project availability, and a low regional horizon does not replace a reading of nearby buildings and vegetation.

Technical location reference

Approximate map point used for Lille, France

This coordinate is the calculation reference for Lille, France. Extra decimal places do not make it a rooftop, property or survey point.

Coordinates and precision
Map coordinate
50.624000000000000000, 3.051100000000000000
Originally displayed coordinate
lat50.624 / long3.0511

How the estimate works

How this Lille estimate was calculated

Here is how I calculated the location estimate for Lille, France.

Read how all Location estimates work

Source and scope

I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.

The figures are calculated estimates, not measured output or a new NASA request while you browse.

Reference period and source details

The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.

NASA POWER project reference

The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.

This source reference does not imply NASA endorsement.

Use the result carefully

What this Lille Location estimate includes and leaves out

Use the Lille figures for broad location context, with the following boundaries in mind.

  • These catalogue estimates are informational; they do not establish a site-specific production result.
  • The location is an approximate reference, not a property, rooftop or survey coordinate.
  • The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
  • The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
  • Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.

Keep exploring

Compare Lille with another location

Back to catalogue

Detailed site analysis

Take it a step further

Whether you’re exploring solar for your own project or comparing options for your clients, profileSOLAR helps you assess historical generation, compare system configurations and produce clear reports.

Detailed analysis for your project or your clients.

Explore features and paid access in the app, or use the complimentary testing access included in your invitation.

Analysis features and access

The profileSOLAR app supports hourly solar analysis over periods of up to five consecutive years, subject to available source data. No electricity-use file is required for this solar analysis.

Compare supported panel configurations, then download Summary or Detailed PDF reports for the saved Analysis.

Testing access includes only the features and allowances stated in your invitation. Your catalogue selection is not transferred; choose your exact site in the app.

Explore detailed site analysis