Location estimate
Brahmapur
Odisha · India
Approximate location reference—not a rooftop, property or survey point.
Seasonal average-day estimates
Selected capacity 1 kWp
Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.
Logarithmic slider: each labelled interval is 10× capacity. Energy scales linearly with capacity.
Arrow keys change capacity by about 2.3 percent per step. Page Up and Page Down move one labelled interval. Home selects 0.1 kWp; End selects 10 MWp.
Enter exact capacity and unit
Enter at least 0.1 kWp. Decimal point or comma; no thousands separators. 1 MWp = 1,000 kWp. Changing units keeps the same capacity. Exact entry keeps your precision; slider adjustments select three-significant-figure sizes.
There is no fixed upper capacity limit. Values and results must fit the calculator’s numeric range; the slider’s range is not an exact-entry limit.
Showing seasonal average-day estimates for 1 kWp.
Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.
Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.
Summer
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Autumn
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Winter
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Spring
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Very large results use scientific notation; an approximate capacity label is marked ≈. Exact capacity and full results remain available under Source basis and scaling limits.
Shared scale: 0–7.00 kWh/day.
I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.
This is illustrative scaling, not a site-specific production prediction.
Source basis and scaling limits
Original seasonal average-day estimates for Brahmapur, in kWh/kWp/day.
I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.
| Season | Recorded kWh/kWp/day | Exact selected-capacity result · kWh/day |
|---|---|---|
| Summer | 4.58 | 4.58 × 1 kWp = 4.58 kWh/day |
| Autumn | 4.30 | 4.30 × 1 kWp = 4.30 kWh/day |
| Winter | 4.70 | 4.70 × 1 kWp = 4.70 kWh/day |
| Spring | 6.08 | 6.08 × 1 kWp = 6.08 kWh/day |
Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.
Full results rounded to two decimal places
These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.
- Summer · kWh/day
- 4.58
- Autumn · kWh/day
- 4.30
- Winter · kWh/day
- 4.70
- Spring · kWh/day
- 6.08
The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.
These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.
Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.
Year-round panel setup
- Tilt from horizontal
- 18°
- Facing direction
- South
Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.
Suggested seasonal tilts
Tilt from horizontal · facing direction
- Summer
Jun, Jul, Aug - 3°South
- Autumn
Sep, Oct, Nov - 25°South
- Winter
Dec, Jan, Feb - 34°South
- Spring
Mar, Apr, May - 13°South
The seasonal electricity figures do not model gains from switching between these settings.
About this orientation
This schematic shows the year-round panel tilt and facing direction for Brahmapur, Odisha, India.
For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.
I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.
The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.
Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.
Seasonal orientation diagrams
These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.
Summer
3° tilt · South
Illustrative direction; exact azimuth not recorded.
Autumn
25° tilt · South
Illustrative direction; exact azimuth not recorded.
Winter
34° tilt · South
Illustrative direction; exact azimuth not recorded.
Spring
13° tilt · South
Illustrative direction; exact azimuth not recorded.
View larger
Hourly electricity pattern for Brahmapur, India
Hourly profiles by season — Brahmapur, India · 2021
This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.
2021 is the method’s reference year, not verified year coverage for every point in this historical chart.
The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.
Row-spacing planning
Planning solar-panel row spacing in Brahmapur
Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.
Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.
Panel and spacing inputs
Along the tilted surface, across the row. Greater than 0, up to 20 m; 2 m is an example.
Optional extra space, 0–100 m.
Starts at the recorded year-round tilt. Decimal entry is kept at your entered precision.
Linear slider: arrows select the next whole degree; Page Up/Down 10°, Home 0°, End 90°. Only moving it changes your numeric entry.
Results update automatically.
Example calculated with a 2 m panel surface length. Replace that example with the dimension of the module you are considering.
Example calculated with a 2 m panel surface length. Replace that example with the dimension of the module you are considering. Other published location estimates remain available.
Adjust the inputs to update this diagram and its results.
Row pitch including margin
≈ m
- Sunlight ray
- First row’s ground shadow
- Shadow endpoint
At this scale the panel surfaces are very small. The row labels locate them; exact dimensions remain available below.
- Calculated clear gap
- ≈ m
- Added margin
- ≈ 0 m
- Gap including margin
- ≈ m
- Panel horizontal footprint
- ≈ m
- Panel vertical rise
- ≈ m
- Pitch before margin
- ≈ m
Simplified level ground, equator-facing cross-section. Approximate Northern Hemisphere winter solstice at solar noon (day 355). The separate recorded facing direction is not an input.
One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.
Detailed inputs and unrounded results
More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.
- Panel surface length
- 2 m
- Tilt up from horizontal
- 18°
- Added margin
- 0 m
- Latitude from the catalogue
- 19.307500000000000000° (Northern Hemisphere)
- Panel horizontal footprint
- 1.902113032590307 m
- Panel vertical rise
- 0.6180339887498948 m
- Calculated clear gap
- 0.5714504456418501 m
- Pitch before margin
- 2.4735634782321574 m
- Gap including margin
- 0.5714504456418501 m
- Row pitch including margin
- 2.4735634782321574 m
- Design solar elevation
- 47.24271715318635°
How this spacing estimate is calculated
I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.
δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).
Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.
The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.
The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.
Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.
Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.
Solar context for Brahmapur
Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.
Brahmapur's plain slopes gently toward the Bay of Bengal, with granite hillocks bounding it to the west and north. This coastal-to-hill setting accompanies a solar profile whose highest estimated daily generation occurs in spring.
Read the full article
Spring averages 6.08 kWh/day per kW of installed capacity. Winter follows at 4.70 kWh/day per kW, then summer at 4.58 kWh/day per kW and autumn at 4.30 kWh/day per kW. Spring is about 41% above autumn. Winter slightly exceeds summer, so the figures do not follow a simple summer-to-winter decline. For fixed panels, our annual output-weighted reference is 18 degrees facing South, calculated using simplified solar geometry. It describes a broad panel orientation before the actual roof position and nearby skyline are considered. The municipal description of the plain and its bounding hillocks gives a useful focus for that local view. A position looking toward the coast may have a different horizon from one close to rising ground, while urban buildings add another layer of nearby obstacles. We would use the actual panel position to understand direct exposure, keeping the spring maximum and the closer grouping of the other three seasons explicit rather than attributing them to unmeasured temperature or equipment effects.
Topography around Brahmapur
These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.
Brahmapur, also commonly written Berhampur, is a major urban centre in Odisha's Ganjam district. The municipal corporation's own geographical account describes a plain with a gentle slope toward the Bay of Bengal, bounded to the west and north by granite hillocks.
Read the full topography description
That arrangement gives the immediate region two clear physical elements: the lower coastal-facing surface and the igneous-rock rises at its inland margins. The plain should therefore be understood in relation to those bounding hills, rather than as an uninterrupted expanse extending equally in every direction. The built city occupies part of this setting. Streets, buildings and vegetation can introduce local changes in the skyline even where the broader land surface is gently inclined. Closer to a hill margin, the height and direction of the rising ground become another part of that view. For solar exposure, we would compare the actual roof or ground position with those features. The broad coastal slope provides geographical context; it does not establish unused land, a particular property gradient or freedom from flooding. The granite hillocks and sea-facing plain are the supported local framework for interpreting the terrain around Brahmapur.
Technical location reference
Approximate map point used for Brahmapur, India
This coordinate is the calculation reference for Brahmapur, India. Extra decimal places do not make it a rooftop, property or survey point.
Coordinates and precision
- Map coordinate
- 19.307500000000000000, 84.793100000000000000
- Originally displayed coordinate
- lat19.3075 / long84.7931
How the estimate works
How this Brahmapur estimate was calculated
Here is how I calculated the location estimate for Brahmapur, India.
Read how all Location estimates workSource and scope
I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.
The figures are calculated estimates, not measured output or a new NASA request while you browse.
Reference period and source details
The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.
NASA POWER project reference
The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.
This source reference does not imply NASA endorsement.
Use the result carefully
What this Brahmapur Location estimate includes and leaves out
Use the Brahmapur figures for broad location context, with the following boundaries in mind.
- These catalogue estimates are informational; they do not establish a site-specific production result.
- The location is an approximate reference, not a property, rooftop or survey coordinate.
- The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
- The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
- Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.