Flag of United States

Flag of MexicoSolar PV Analysis of Campo Sesenta Y Cuatro B, Mexico

Graph of hourly avg kWh electricity output per kW of Solar PV installed in Campo Sesenta Y Cuatro B, Mexico (by season)

Campo Sesenta y Cuatro B, Mexico represents a highly favorable location for year-round solar energy generation. This Northern Sub Tropics site demonstrates excellent solar potential across all seasons, making it an ideal candidate for solar PV installations.

Seasonal Solar Performance

The location shows strong seasonal variation in solar output, with spring delivering the highest energy production at 7.92 kWh per day per kW of installed capacity. Summer follows closely with 7.47 kWh/day per kW, creating an extended period of peak solar generation from approximately March through September. Autumn production drops to 5.77 kWh/day per kW, while winter represents the lowest output period at 4.65 kWh/day per kW. However, even during the least productive winter months, the location still generates substantial solar energy, indicating consistent year-round viability.

Optimal Installation Configuration

For maximum year-round energy production at Campo Sesenta y Cuatro B, solar panels should be installed at a fixed tilt angle of 26 degrees facing south. This angle has been calculated to optimize total annual solar output by accounting for the sun's changing position throughout the year and weighting for daily solar irradiance potential.

Environmental Factors and Mitigation Strategies

Several environmental factors common to this desert region of northern Mexico could potentially impact solar production:
  • Dust and sand accumulation: The arid desert climate generates significant airborne particles that can coat solar panels, reducing their efficiency by 10-25% if left uncleaned
  • Extreme temperature variations: Desert locations experience large daily temperature swings that can stress solar equipment and reduce panel efficiency during peak heat periods
  • Occasional dust storms: Seasonal weather patterns may bring intense dust storms that can rapidly coat panels and temporarily reduce output

Recommended Preventative Measures

To maintain optimal solar production at this location, several installation strategies should be implemented:
  • Regular cleaning schedule: Establish monthly panel cleaning routines, with increased frequency during dusty seasons
  • Improved ventilation design: Install panels with adequate spacing beneath for air circulation to manage heat buildup
  • Dust-resistant mounting: Use sealed electrical connections and choose equipment rated for harsh desert environments
  • Monitoring systems: Install performance monitoring to quickly identify when dust accumulation or other factors reduce output
Despite these environmental challenges, Campo Sesenta y Cuatro B remains an excellent location for solar energy generation. The consistently high solar irradiance levels throughout the year far outweigh the manageable environmental factors, making this location highly suitable for both residential and commercial solar installations with proper maintenance protocols.

Note: The Northern Sub Tropics extend from 23.5° latitude North up to 35° latitude.

So far, we have conducted calculations to evaluate the solar photovoltaic (PV) potential in 358 locations across Mexico. This analysis provides insights into each city/location's potential for harnessing solar energy through PV installations.

Link: Solar PV potential in Mexico by location

Solar output per kW of installed solar PV by season in Campo Sesenta Y Cuatro B

Seasonal solar PV output for Latitude: 29.0289, Longitude: -106.6811 (Campo Sesenta Y Cuatro B, Mexico), based on our analysis of 8760 hourly intervals of solar and meteorological data (one whole year) retrieved for that set of coordinates/location from NASA POWER (The Prediction of Worldwide Energy Resources) API:

Summer
Average 7.47kWh/day in Summer.
Autumn
Average 5.77kWh/day in Autumn.
Winter
Average 4.65kWh/day in Winter.
Spring
Average 7.92kWh/day in Spring.

 

Ideally tilt fixed solar panels 26° South in Campo Sesenta Y Cuatro B, Mexico

To maximize your solar PV system's energy output in Campo Sesenta Y Cuatro B, Mexico (Lat/Long 29.0289, -106.6811) throughout the year, you should tilt your panels at an angle of 26° South for fixed panel installations.

As the Earth revolves around the Sun each year, the maximum angle of elevation of the Sun varies by +/- 23.45 degrees from its equinox elevation angle for a particular latitude. Finding the exact optimal angle to maximise solar PV production throughout the year can be challenging, but with careful consideration of historical solar energy and meteorological data for a certain location, it can be done precisely.

We use our own calculation, which incorporates NASA solar and meteorological data for the exact Lat/Long coordinates, to determine the ideal tilt angle of a solar panel that will yield maximum annual solar output. We calculate the optimal angle for each day of the year, taking into account its contribution to the yearly total PV potential at that specific location.

The sun
At Latitude: 29.0289, Longitude: -106.6811, the ideal angle to tilt panels is 26° South

Seasonally adjusted solar panel tilt angles for Campo Sesenta Y Cuatro B, Mexico

If you can adjust the tilt angle of your solar PV panels, please refer to the seasonal tilt angles below for optimal solar energy production in Campo Sesenta Y Cuatro B, Mexico. As mentioned earlier, for fixed-panel solar PV installations, it is optimal to maintain a 26° South tilt angle throughout the year.

Overall Best Summer Angle Overall Best Autumn Angle Overall Best Winter Angle Overall Best Spring Angle
13° South in Summer 34° South in Autumn 44° South in Winter 22° South in Spring

Assuming you can modify the tilt angle of your solar PV panels throughout the year, you can optimize your solar generation in Campo Sesenta Y Cuatro B, Mexico as follows: In Summer, set the angle of your panels to 13° facing South. In Autumn, tilt panels to 34° facing South for maximum generation. During Winter, adjust your solar panels to a 44° angle towards the South for optimal energy production. Lastly, in Spring, position your panels at a 22° angle facing South to capture the most solar energy in Campo Sesenta Y Cuatro B, Mexico.

Our recommendations take into account more than just latitude and Earth's position in its elliptical orbit around the Sun. We also incorporate historical solar and meteorological data from NASA's Prediction of Worldwide Energy Resources (POWER) API to assign a weight to each ideal angle for each day based on its historical contribution to overall solar PV potential during a specific season.

This approach allows us to provide much more accurate recommendations than relying solely on latitude, as it considers unique weather conditions in different locations sharing the same latitude worldwide.

Calculate solar panel row spacing in Campo Sesenta Y Cuatro B, Mexico

We've added a feature to calculate minimum solar panel row spacing by location. Enter your panel size and orientation below to get the minimum spacing in Campo Sesenta Y Cuatro B, Mexico.

Our calculation method

  1. Solar Position:
    We determine the Sun's position on the Winter solstice using the location's latitude and solar declination.
  2. Shadow Projection:
    We calculate the shadow length cast by panels using trigonometry, considering panel tilt and the Sun's elevation angle.
  3. Minimum Spacing:
    We add the shadow length to the horizontal space occupied by tilted panels.

This approach ensures maximum space efficiency while avoiding shading during critical times, as the Winter solstice represents the worst-case scenario for shadow length.






Please enter information above to calculate panel spacing.

Topography for solar PV around Campo Sesenta Y Cuatro B, Mexico

Topographical Features Around Campo Sesenta y Cuatro B

The landscape surrounding Campo Sesenta y Cuatro B in northern Mexico presents a predominantly flat to gently rolling terrain characteristic of the Chihuahuan Desert region. This area lies within a broad basin surrounded by distant mountain ranges, creating an expansive plain that stretches across much of the northern Chihuahua state. The elevation remains relatively consistent across the immediate vicinity, with subtle undulations that rarely exceed modest slopes. The terrain consists primarily of desert scrubland with sparse vegetation, including scattered mesquite, creosote bush, and various cacti species adapted to the arid environment. The soil composition is typically sandy to gravelly, with areas of hardpan caliche beneath the surface layer. Seasonal arroyos and dry washes cut through the landscape, though these drainage features are generally shallow and infrequent in this particular region.

Mountain Ranges and Geographic Context

While the immediate area around Campo Sesenta y Cuatro B remains relatively flat, the broader regional topography includes several mountain ranges visible on the horizon. The Sierra Madre Occidental lies to the southwest, while smaller mountain chains dot the landscape at considerable distances. These elevated features do not significantly impact the local terrain but contribute to the overall basin-and-range topography typical of northern Mexico. The location sits within what geographers classify as an intermontane basin, meaning it occupies the relatively flat area between mountain ranges. This positioning creates favorable conditions for large-scale development projects, as the terrain presents minimal obstacles and offers extensive areas of consistent elevation and slope.

Optimal Areas for Large-Scale Solar Development

The most suitable locations for extensive solar photovoltaic installations would be the broad, flat expanses extending north and east of Campo Sesenta y Cuatro B. These areas offer several advantages including minimal grading requirements, consistent terrain that simplifies installation logistics, and sufficient space for massive solar arrays without significant topographical constraints. The northeastern quadrant appears particularly well-suited for solar development due to its exceptionally flat profile and minimal vegetation density. This region would require less land preparation and presents fewer obstacles for construction equipment and materials transport. The terrain's consistency would allow for standardized mounting systems and simplified electrical infrastructure layout. Areas to the south and southwest, while still generally suitable, contain slightly more varied topography with occasional low hills and more pronounced drainage features. These locations might require additional site preparation but could still accommodate large-scale solar installations with proper planning and minimal earthwork. The western areas present mixed suitability, with some excellent flat zones interspersed with more challenging terrain featuring steeper grades and more complex drainage patterns. However, selective development of the flatter portions within this western zone could still yield substantial solar generation capacity.

Mexico solar PV Stats as a country

Mexico ranks 18th in the world for cumulative solar PV capacity, with 7,040 total MW's of solar PV installed. This means that 3.20% of Mexico's total energy as a country comes from solar PV (that's 28th in the world). Each year Mexico is generating 55 Watts from solar PV per capita (Mexico ranks 50th in the world for solar PV Watts generated per capita). [source]

Are there incentives for businesses to install solar in Mexico?

Yes, there are several incentives for businesses wanting to install solar energy in Mexico. The Mexican government offers a range of financial incentives and tax breaks for businesses that invest in renewable energy projects. These include grants, loans, and subsidies for the purchase of equipment and installation costs. Additionally, businesses can benefit from net metering programs which allow them to sell excess electricity back to the grid at a premium rate. Finally, businesses may also be eligible for additional benefits such as reduced import duties on solar equipment or accelerated depreciation allowances on investments in renewable energy projects.

Do you have more up to date information than this on incentives towards solar PV projects in Mexico? Please reach out to us and help us keep this information current. Thanks!

Citation Guide

Article Details for Citation

Article: Solar PV Analysis of Campo Sesenta Y Cuatro B, Mexico
Author: Aaron Robinson
Publisher: profileSOLAR.com
First Published: Saturday 19th of July 2025
Last Updated: Thursday 7th of August 2025

Tell Us About Your Work

We love seeing how our research helps others! If you've cited this article in your work, we'd be delighted to hear about it. Drop us a line via our Contact Us page or on X, to share where you've used our information - we may feature a link to your work on our site. This helps create a network of valuable resources for others in the solar energy community and helps us understand how our research is contributing to the field. Plus, we occasionally highlight exceptional works that reference our research on our social media channels.

Feeling generous?

"Así como el sol le da chispa a los paneles solares, el café nos pone las pilas para seguir echándole ganitas a nuestra investigación y desarrollo." 😊
Buy me a coffee - Thanks for your support!

Share this with your friends!



Compare this location to others worldwide for solar PV potential

The solar PV analyses available on our website, including this one, are offered as a free service to the global community. Our aim is to provide education and aid informed decision-making regarding solar PV installations.

However, please note that these analyses are general guidance and may not meet specific project requirements. For in-depth, tailored forecasts and analysis crucial for feasibility studies or when pursuing maximum ROI from your solar projects, feel free to contact us; we offer comprehensive consulting services expressly for this purpose.

Worldwide Solar PV Analysis of 20,000 Locations

Helping you assess viability of solar PV for your site

profileSOLAR on YouTube

Calculate Your Optimal Solar Panel Tilt Angle: A Comprehensive Guide

Enhance your solar panel's performance with our in-depth guide. Determine the best tilt angle using hard data, debunk common misunderstandings, and gain insight into how your specific location affects solar energy production.

Calculate Your Optimal Solar Panel Tilt Angle