Location estimate

Lucban

Calabarzon · Philippines

Approximate location reference—not a rooftop, property or survey point.

Seasonal average-day estimates

Selected capacity 1 kWp

Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.

Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.

Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.

Summer

5.28

kWh/day

Autumn

5.18

kWh/day

Winter

5.07

kWh/day

Spring

6.85

kWh/day

Shared scale: 0–7.00 kWh/day.

I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.

This is illustrative scaling, not a site-specific production prediction.

Source basis and scaling limits

Original seasonal average-day estimates for Lucban, in kWh/kWp/day.

I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.

Original source values and selected-capacity calculation
SeasonRecorded kWh/kWp/dayExact selected-capacity result · kWh/day
Summer 5.28 5.28 × 1 kWp = 5.28 kWh/day
Autumn 5.18 5.18 × 1 kWp = 5.18 kWh/day
Winter 5.07 5.07 × 1 kWp = 5.07 kWh/day
Spring 6.85 6.85 × 1 kWp = 6.85 kWh/day

Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.

Full results rounded to two decimal places

These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.

Summer · kWh/day
5.28
Autumn · kWh/day
5.18
Winter · kWh/day
5.07
Spring · kWh/day
6.85

The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.

These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Year-round panel setup

Schematic catalogue setting — Year-round fixed panel setup: tilt 13 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Year-round fixed panel setup · schematic
Tilt from horizontal
13°
Facing direction
South

Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.

Suggested seasonal tilts

Tilt from horizontal · facing direction

Summer
Jun, Jul, Aug
2°North
Autumn
Sep, Oct, Nov
20°South
Winter
Dec, Jan, Feb
29°South
Spring
Mar, Apr, May
7°South

The seasonal electricity figures do not model gains from switching between these settings.

About this orientation

This schematic shows the year-round panel tilt and facing direction for Lucban, Calabarzon, Philippines.

For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.

I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.

The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.

Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.

Seasonal orientation diagrams

These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.

Summer

Schematic catalogue setting — Summer panel setup: tilt 2 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Summer panel setup · schematic

2° tilt · North

Illustrative direction; exact azimuth not recorded.

Autumn

Schematic catalogue setting — Autumn panel setup: tilt 20 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Autumn panel setup · schematic

20° tilt · South

Illustrative direction; exact azimuth not recorded.

Winter

Schematic catalogue setting — Winter panel setup: tilt 29 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Winter panel setup · schematic

29° tilt · South

Illustrative direction; exact azimuth not recorded.

Spring

Schematic catalogue setting — Spring panel setup: tilt 7 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Spring panel setup · schematic

7° tilt · South

Illustrative direction; exact azimuth not recorded.

Historical hourly-by-season solar output chart for Lucban, Philippines. View larger
Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

Hourly electricity pattern for Lucban, Philippines

Hourly profiles by season — Lucban, Philippines · 2021

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

2021 is the method’s reference year, not verified year coverage for every point in this historical chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.

Historical hourly chart

Hourly profiles by season — Lucban, Philippines · 2021

Swipe to pan, or focus the chart and use arrow keys.

Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern.

2021 is the method’s reference year, not verified year coverage for every plotted point.

Enlargement is limited to the original image resolution.

Row-spacing planning

Planning solar-panel row spacing in Lucban

Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.

Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.

Row pitch including margin

≈ 2.29 m

Proportional side viewDesign sun: ≈ 52.6° above horizontal
Row 1 Row 2 Clear gap Added margin: 0 m Row pitch including margin
  • Sunlight ray
  • First row’s ground shadow
  • Shadow endpoint
Calculated clear gap
≈ 0.34 m
Added margin
≈ 0 m
Gap including margin
≈ 0.34 m
Panel horizontal footprint
≈ 1.95 m
Panel vertical rise
≈ 0.45 m
Pitch before margin
≈ 2.29 m

Simplified level ground, equator-facing cross-section. Approximate Northern Hemisphere winter solstice at solar noon (day 355). The separate recorded facing direction is not an input.

One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.

Detailed inputs and unrounded results

More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.

Panel surface length
2 m
Tilt up from horizontal
13°
Added margin
0 m
Latitude from the catalogue
13.951200000000000000° (Northern Hemisphere)
Panel horizontal footprint
1.9487401295704705 m
Panel vertical rise
0.44990210868772995 m
Calculated clear gap
0.3439883644183262 m
Pitch before margin
2.292728493988797 m
Gap including margin
0.3439883644183262 m
Row pitch including margin
2.292728493988797 m
Design solar elevation
52.599017153186345°
How this spacing estimate is calculated

I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.

δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).

Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.

The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.

The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.

Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Solar context for Lucban

Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.

<p>Lucban, Philippines, situated at 13.9512°N, 120.7562°E, offers a promising location for solar energy generation. This tropical locale experiences consistent sunlight throughout the year, with seasons primarily characterized by wet and dry periods rather than temperature variations.</p>

Read the full article

<h3>Seasonal Solar Performance</h3> <p>Solar panel efficiency in Lucban demonstrates remarkable consistency across seasons, with a notable peak during spring. The average daily electricity output per kilowatt of installed solar capacity is as follows:</p> <ul> <li>Spring: 6.85 kWh/day</li> <li>Summer: 5.28 kWh/day</li> <li>Autumn: 5.18 kWh/day</li> <li>Winter: 5.07 kWh/day</li> </ul> <p>Spring emerges as the most productive season, likely due to clearer skies and optimal sun angles. The relatively small variation between other seasons indicates reliable year-round solar potential.</p> <h3>Optimal Panel Tilt</h3> <p>For fixed solar panel installations in Lucban, the ideal tilt angle to maximize year-round energy production is 13 degrees facing South. This angle optimizes the panels' exposure to sunlight throughout the year, accounting for the location's latitude and the Earth's orbit.</p> <h3>Environmental Considerations</h3> <p>While Lucban's tropical climate is generally favorable for solar energy, there are some environmental factors to consider:</p> <p>1. Typhoons: The Philippines is prone to tropical cyclones, which can potentially damage solar installations. To mitigate this risk, robust mounting systems and high-quality, weather-resistant panels should be used.</p> <p>2. Heavy Rainfall: The region experiences a pronounced rainy season, typically from June to November. While modern solar panels can still generate electricity in overcast conditions, heavy cloud cover will reduce efficiency. Installing slightly more capacity than needed can help offset these seasonal variations.</p> <p>3. High Humidity: The tropical climate's high humidity can potentially lead to moisture-related issues in solar equipment. Using corrosion-resistant materials and ensuring proper sealing of all components can prevent long-term damage.</p> <p>Despite these challenges, with proper planning and installation techniques, Lucban presents an excellent opportunity for consistent, year-round solar energy production. The minimal seasonal variation in output, combined with the high spring performance, makes it an attractive location for solar PV systems.</p>

Topography around Lucban

These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.

<p>The topography around Lucban, Philippines, is characterized by a diverse landscape that combines rolling hills, lush valleys, and gentle slopes. Situated at the foot of Mount Banahaw, Lucban is nestled in a region known for its picturesque terrain and fertile soil. The area is part of the larger Quezon Province, which features a mix of lowlands and mountainous regions.</p>

Read the full topography description

<p>To the north and east of Lucban, the land gradually rises towards the slopes of Mount Banahaw, a dormant volcano that dominates the skyline. This mountain range creates a natural backdrop for the town and influences local weather patterns. As you move away from the mountain, the terrain becomes more varied, with undulating hills interspersed with flat areas and small river valleys.</p> <p>To the south and west, the landscape becomes generally flatter, transitioning into the broader plains of Quezon Province. This area is characterized by a patchwork of agricultural fields, small forests, and scattered settlements. The region also features numerous streams and rivers that flow down from the mountains, creating a network of waterways that shape the local topography.</p> <p>When considering areas nearby that would be most suited for large-scale solar PV (photovoltaic) installations, the flatter regions to the south and west of Lucban present the most promising opportunities. These areas offer several advantages for solar energy production:</p> <ol> <li>The relatively flat terrain makes it easier and more cost-effective to install large arrays of solar panels.</li> <li>There are fewer natural obstacles like tall trees or steep hills that could cast shadows on the panels, maximizing sun exposure throughout the day.</li> <li>The open spaces in these agricultural areas provide ample room for expansive solar farms without significant land use conflicts.</li> <li>The proximity to existing infrastructure and settlements could facilitate easier grid connection and maintenance access.</li> </ol> <p>However, it's important to note that any large-scale solar PV project would require detailed site-specific assessments, including soil stability studies, environmental impact evaluations, and considerations for local land use regulations. Additionally, while the flatter areas may be most suitable, advances in solar technology have made it increasingly feasible to install solar panels on moderately sloping terrain, potentially opening up more options in the hilly regions around Lucban as well.</p>

Technical location reference

Approximate map point used for Lucban, Philippines

This coordinate is the calculation reference for Lucban, Philippines. Extra decimal places do not make it a rooftop, property or survey point.

Coordinates and precision
Map coordinate
13.951200000000000000, 120.756200000000000000
Originally displayed coordinate
lat13.9512 / long120.7562

How the estimate works

How this Lucban estimate was calculated

Here is how I calculated the location estimate for Lucban, Philippines.

Read how all Location estimates work

Source and scope

I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.

The figures are calculated estimates, not measured output or a new NASA request while you browse.

Reference period and source details

The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.

NASA POWER project reference

The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.

This source reference does not imply NASA endorsement.

Use the result carefully

What this Lucban Location estimate includes and leaves out

Use the Lucban figures for broad location context, with the following boundaries in mind.

  • These catalogue estimates are informational; they do not establish a site-specific production result.
  • The location is an approximate reference, not a property, rooftop or survey coordinate.
  • The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
  • The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
  • Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.

Keep exploring

Compare Lucban with another location

Back to country results

Detailed site analysis

Take it a step further

Whether you’re exploring solar for your own project or comparing options for your clients, profileSOLAR helps you assess historical generation, compare system configurations and produce clear reports.

Detailed analysis for your project or your clients.

Explore features and paid access in the app, or use the complimentary testing access included in your invitation.

Analysis features and access

The profileSOLAR app supports hourly solar analysis over periods of up to five consecutive years, subject to available source data. No electricity-use file is required for this solar analysis.

Compare supported panel configurations, then download Summary or Detailed PDF reports for the saved Analysis.

Testing access includes only the features and allowances stated in your invitation. Your catalogue selection is not transferred; choose your exact site in the app.

Explore detailed site analysis