Location estimate

Magalang

Central Luzon · Philippines

Approximate location reference—not a rooftop, property or survey point.

Seasonal average-day estimates

Selected capacity 1 kWp

Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.

Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.

Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.

Summer

5.36

kWh/day

Autumn

5.36

kWh/day

Winter

5.22

kWh/day

Spring

6.94

kWh/day

Shared scale: 0–7.00 kWh/day.

I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.

This is illustrative scaling, not a site-specific production prediction.

Source basis and scaling limits

Original seasonal average-day estimates for Magalang, in kWh/kWp/day.

I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.

Original source values and selected-capacity calculation
SeasonRecorded kWh/kWp/dayExact selected-capacity result · kWh/day
Summer 5.36 5.36 × 1 kWp = 5.36 kWh/day
Autumn 5.36 5.36 × 1 kWp = 5.36 kWh/day
Winter 5.22 5.22 × 1 kWp = 5.22 kWh/day
Spring 6.94 6.94 × 1 kWp = 6.94 kWh/day

Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.

Full results rounded to two decimal places

These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.

Summer · kWh/day
5.36
Autumn · kWh/day
5.36
Winter · kWh/day
5.22
Spring · kWh/day
6.94

The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.

These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Year-round panel setup

Schematic catalogue setting — Year-round fixed panel setup: tilt 14 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Year-round fixed panel setup · schematic
Tilt from horizontal
14°
Facing direction
South

Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.

Suggested seasonal tilts

Tilt from horizontal · facing direction

Summer
Jun, Jul, Aug
1°North
Autumn
Sep, Oct, Nov
21°South
Winter
Dec, Jan, Feb
31°South
Spring
Mar, Apr, May
8°South

The seasonal electricity figures do not model gains from switching between these settings.

About this orientation

This schematic shows the year-round panel tilt and facing direction for Magalang, Central Luzon, Philippines.

For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.

I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.

The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.

Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.

Seasonal orientation diagrams

These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.

Summer

Schematic catalogue setting — Summer panel setup: tilt 1 degrees above horizontal; facing North. Direction is illustrative; exact azimuth not recorded.NESW
Summer panel setup · schematic

1° tilt · North

Illustrative direction; exact azimuth not recorded.

Autumn

Schematic catalogue setting — Autumn panel setup: tilt 21 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Autumn panel setup · schematic

21° tilt · South

Illustrative direction; exact azimuth not recorded.

Winter

Schematic catalogue setting — Winter panel setup: tilt 31 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Winter panel setup · schematic

31° tilt · South

Illustrative direction; exact azimuth not recorded.

Spring

Schematic catalogue setting — Spring panel setup: tilt 8 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Spring panel setup · schematic

8° tilt · South

Illustrative direction; exact azimuth not recorded.

Historical hourly-by-season solar output chart for Magalang, Philippines. View larger
Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

Hourly electricity pattern for Magalang, Philippines

Hourly profiles by season — Magalang, Philippines · 2021

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

2021 is the method’s reference year, not verified year coverage for every point in this historical chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.

Historical hourly chart

Hourly profiles by season — Magalang, Philippines · 2021

Swipe to pan, or focus the chart and use arrow keys.

Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern.

2021 is the method’s reference year, not verified year coverage for every plotted point.

Enlargement is limited to the original image resolution.

Row-spacing planning

Planning solar-panel row spacing in Magalang

Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.

Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.

Row pitch including margin

≈ 2.33 m

Proportional side viewDesign sun: ≈ 51.33° above horizontal
Row 1 Row 2 Clear gap Added margin: 0 m Row pitch including margin
  • Sunlight ray
  • First row’s ground shadow
  • Shadow endpoint
Calculated clear gap
≈ 0.39 m
Added margin
≈ 0 m
Gap including margin
≈ 0.39 m
Panel horizontal footprint
≈ 1.94 m
Panel vertical rise
≈ 0.48 m
Pitch before margin
≈ 2.33 m

Simplified level ground, equator-facing cross-section. Approximate Northern Hemisphere winter solstice at solar noon (day 355). The separate recorded facing direction is not an input.

One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.

Detailed inputs and unrounded results

More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.

Panel surface length
2 m
Tilt up from horizontal
14°
Added margin
0 m
Latitude from the catalogue
15.220900000000000000° (Northern Hemisphere)
Panel horizontal footprint
1.940591452551993 m
Panel vertical rise
0.48384379119933546 m
Calculated clear gap
0.3872256608317308 m
Pitch before margin
2.3278171133837238 m
Gap including margin
0.3872256608317308 m
Row pitch including margin
2.3278171133837238 m
Design solar elevation
51.32931715318635°
How this spacing estimate is calculated

I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.

δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).

Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.

The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.

The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.

Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Solar context for Magalang

Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.

Magalang’s landscape is defined by the contrast between the Pampanga plain and Mount Arayat. Our solar estimate gives spring the highest seasonal average: 6.94 kWh/day for each 1 kW of rated panel capacity. Summer and autumn are both 5.36 kWh/day, while winter is 5.22 kWh/day. These are estimated average daily electricity values, with appreciable variation still possible between individual days.

Read the full article

The similar summer and autumn figures are useful when comparing generation with regular daytime demand. Spring’s higher average provides a different planning condition, but it should not be used as the daily expectation for the rest of the year. Electricity use, the installed capacity and the actual roof arrangement all remain part of that comparison. For fixed panels, our year-round reference is 14° facing South. It is a broad output-weighted setting based on simplified solar geometry. The recorded reference does not measure the horizon from a particular house or farm building at the foot of Mount Arayat. That mountain-to-plain relationship gives Magalang a clear local question: what does the sky actually look like from the mounting position? A roof facing towards open agricultural land can have a different outlook from a site nearer rising terrain or tall vegetation. The relevant obstruction is its position and apparent height from the panels, not simply the mountain’s presence on a regional map. Heavy weather also makes secure construction and a workable maintenance route important practical matters. They are addressed through the actual roof, mounting design and local conditions rather than a promise that a particular coating or component prevents storm damage. This keeps the seasonal resource useful without treating it as a complete design for every property in Magalang.

Topography around Magalang

These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.

Magalang lies on the Pampanga side of the Central Luzon plain beside the prominent relief of Mount Arayat. The broad agricultural ground and the rising mountain create a strong contrast, with settlements, fields and local waterways occupying the lower landscape.

Read the full topography description

The mountain is an isolated landmark within the wider plain. Its flanks introduce slopes and vegetation that differ markedly from the cultivated lowlands. The Mount Arayat Protected Landscape borders the municipalities of Arayat and Magalang, making its ecological role part of the local context as well as its visible shape. Across the plain, relatively small changes in level and the arrangement of channels are important to the way water moves. The National Water Resources Board describes Mount Arayat within the middle-to-lower Pampanga basin setting, where river systems, low-lying land and flood storage form a connected landscape. A field that appears level in a photograph can still be crossed by drainage routes or serve a seasonal water-management function. For solar planning, the useful distinction is between an existing building, a working field and the more elevated or wooded ground near the mountain. Each presents different surroundings and access, even though all belong to the same municipality. A roof assessment can examine the mountain and trees within its actual horizon, while a ground proposal needs to work with the field’s drainage and ongoing use. The open plain is therefore a setting to understand rather than a preselected development zone. Its agricultural character and the protected mountain remain defining features of Magalang; neither a general slope description nor a compass direction establishes which individual parcel could accommodate an installation.

Technical location reference

Approximate map point used for Magalang, Philippines

This coordinate is the calculation reference for Magalang, Philippines. Extra decimal places do not make it a rooftop, property or survey point.

Coordinates and precision
Map coordinate
15.220900000000000000, 120.655500000000000000
Originally displayed coordinate
lat15.2209 / long120.6555

How the estimate works

How this Magalang estimate was calculated

Here is how I calculated the location estimate for Magalang, Philippines.

Read how all Location estimates work

Source and scope

I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.

The figures are calculated estimates, not measured output or a new NASA request while you browse.

Reference period and source details

The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.

NASA POWER project reference

The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.

This source reference does not imply NASA endorsement.

Use the result carefully

What this Magalang Location estimate includes and leaves out

Use the Magalang figures for broad location context, with the following boundaries in mind.

  • These catalogue estimates are informational; they do not establish a site-specific production result.
  • The location is an approximate reference, not a property, rooftop or survey coordinate.
  • The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
  • The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
  • Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.

Keep exploring

Compare Magalang with another location

Back to country results

Detailed site analysis

Take it a step further

Whether you’re exploring solar for your own project or comparing options for your clients, profileSOLAR helps you assess historical generation, compare system configurations and produce clear reports.

Detailed analysis for your project or your clients.

Explore features and paid access in the app, or use the complimentary testing access included in your invitation.

Analysis features and access

The profileSOLAR app supports hourly solar analysis over periods of up to five consecutive years, subject to available source data. No electricity-use file is required for this solar analysis.

Compare supported panel configurations, then download Summary or Detailed PDF reports for the saved Analysis.

Testing access includes only the features and allowances stated in your invitation. Your catalogue selection is not transferred; choose your exact site in the app.

Explore detailed site analysis