Location estimate
Batley
England · United Kingdom
Approximate location reference—not a rooftop, property or survey point.
Seasonal average-day estimates
Selected capacity 1 kWp
Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.
Logarithmic slider: each labelled interval is 10× capacity. Energy scales linearly with capacity.
Arrow keys change capacity by about 2.3 percent per step. Page Up and Page Down move one labelled interval. Home selects 0.1 kWp; End selects 10 MWp.
Enter exact capacity and unit
Enter at least 0.1 kWp. Decimal point or comma; no thousands separators. 1 MWp = 1,000 kWp. Changing units keeps the same capacity. Exact entry keeps your precision; slider adjustments select three-significant-figure sizes.
There is no fixed upper capacity limit. Values and results must fit the calculator’s numeric range; the slider’s range is not an exact-entry limit.
Showing seasonal average-day estimates for 1 kWp.
Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.
Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.
Summer
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Autumn
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Winter
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Spring
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Very large results use scientific notation; an approximate capacity label is marked ≈. Exact capacity and full results remain available under Source basis and scaling limits.
Shared scale: 0–6.00 kWh/day.
I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.
This is illustrative scaling, not a site-specific production prediction.
Source basis and scaling limits
Original seasonal average-day estimates for Batley, in kWh/kWp/day.
I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.
| Season | Recorded kWh/kWp/day | Exact selected-capacity result · kWh/day |
|---|---|---|
| Summer | 5.09 | 5.09 × 1 kWp = 5.09 kWh/day |
| Autumn | 2.08 | 2.08 × 1 kWp = 2.08 kWh/day |
| Winter | 0.96 | 0.96 × 1 kWp = 0.96 kWh/day |
| Spring | 4.27 | 4.27 × 1 kWp = 4.27 kWh/day |
Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.
Full results rounded to two decimal places
These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.
- Summer · kWh/day
- 5.09
- Autumn · kWh/day
- 2.08
- Winter · kWh/day
- 0.96
- Spring · kWh/day
- 4.27
The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.
These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.
Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.
Year-round panel setup
- Tilt from horizontal
- 46°
- Facing direction
- South
Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.
Suggested seasonal tilts
Tilt from horizontal · facing direction
- Summer
Jun, Jul, Aug - 37°South
- Autumn
Sep, Oct, Nov - 57°South
- Winter
Dec, Jan, Feb - 67°South
- Spring
Mar, Apr, May - 46°South
The seasonal electricity figures do not model gains from switching between these settings.
About this orientation
This schematic shows the year-round panel tilt and facing direction for Batley, England, United Kingdom.
For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.
I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.
The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.
Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.
Seasonal orientation diagrams
These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.
Summer
37° tilt · South
Illustrative direction; exact azimuth not recorded.
Autumn
57° tilt · South
Illustrative direction; exact azimuth not recorded.
Winter
67° tilt · South
Illustrative direction; exact azimuth not recorded.
Spring
46° tilt · South
Illustrative direction; exact azimuth not recorded.
View larger
Hourly electricity pattern for Batley, United Kingdom
Hourly profiles by season — Batley, United Kingdom · 2021
This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.
2021 is the method’s reference year, not verified year coverage for every point in this historical chart.
The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.
Row-spacing planning
Planning solar-panel row spacing in Batley
Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.
Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.
Panel and spacing inputs
Along the tilted surface, across the row. Greater than 0, up to 20 m; 2 m is an example.
Optional extra space, 0–100 m.
Starts at the recorded year-round tilt. Decimal entry is kept at your entered precision.
Linear slider: arrows select the next whole degree; Page Up/Down 10°, Home 0°, End 90°. Only moving it changes your numeric entry.
Results update automatically.
Example calculated with a 2 m panel surface length. Replace that example with the dimension of the module you are considering.
Example calculated with a 2 m panel surface length. Replace that example with the dimension of the module you are considering. Other published location estimates remain available.
Adjust the inputs to update this diagram and its results.
Row pitch including margin
≈ m
- Sunlight ray
- First row’s ground shadow
- Shadow endpoint
At this scale the panel surfaces are very small. The row labels locate them; exact dimensions remain available below.
- Calculated clear gap
- ≈ m
- Added margin
- ≈ 0 m
- Gap including margin
- ≈ m
- Panel horizontal footprint
- ≈ m
- Panel vertical rise
- ≈ m
- Pitch before margin
- ≈ m
Simplified level ground, equator-facing cross-section. Approximate Northern Hemisphere winter solstice at solar noon (day 355). The separate recorded facing direction is not an input.
One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.
Detailed inputs and unrounded results
More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.
- Panel surface length
- 2 m
- Tilt up from horizontal
- 46°
- Added margin
- 0 m
- Latitude from the catalogue
- 53.703700000000000000° (Northern Hemisphere)
- Panel horizontal footprint
- 1.3893167409179947 m
- Panel vertical rise
- 1.4386796006773022 m
- Calculated clear gap
- 6.308659929729778 m
- Pitch before margin
- 7.697976670647773 m
- Gap including margin
- 6.308659929729778 m
- Row pitch including margin
- 7.697976670647773 m
- Design solar elevation
- 12.846517153186353°
How this spacing estimate is calculated
I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.
δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).
Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.
The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.
The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.
Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.
Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.
Solar context for Batley
Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.
Batley's solar estimates show a large seasonal difference. Summer averages 5.09 kWh/day per kW of rated capacity and spring 4.27 kWh/day. Autumn averages 2.08 kWh/day, falling to 0.96 kWh/day in winter. These are estimated seasonal daily averages, so the stronger summer contribution and smaller winter contribution should be compared separately with electricity demand.
Read the full article
For fixed panels, our reference is 46 degrees facing South. It is a broad output-weighted reference using simplified solar geometry. The roof planes available on a building and the surrounding horizon shape the practical arrangement. Batley's setting includes hills, valleys and closely connected built-up areas. A nearby slope or opposing roofline can affect when sunlight reaches panels, while trees add more local shade. These sight lines become particularly relevant to the lower winter sun. The energy figures offer a baseline for evaluating the contribution of solar over the year. Coatings, cleaning and snow-management equipment have separate functions and requirements; their use follows the actual modules and roof conditions. Comparing the seasonal generation with demand helps show the array's contribution, especially during the smaller winter period.
Topography around Batley
These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.
Batley belongs to the hill-and-valley landscape of the Batley and Spen area. Kirklees' own landscape account relates the settlements to the Spen and Calder valleys, whose landforms are generally wider and less steep than some other parts of the district. Built-up Batley, Heckmondwike and Dewsbury are closely connected within that setting.
Read the full topography description
The town's fringe includes smaller stream valleys extending into the surrounding farmland. The regional landscape study describes shallow depressions with a mixture of pasture and woodland, sometimes giving an enclosed rural character close to urban areas. Oakwell Country Park is one of the named places within this fringe landscape. This combination of settled hills and smaller green valleys gives local differences in exposure. Buildings on opposing slopes, woodland edges and the direction of a valley can all affect the horizon seen from a roof. For solar panels, those immediate features give each roof or ground surface a distinct setting within the hill-and-valley landscape. A ground-mounted layout also needs to fit the existing pasture, woodland and stream routes as well as the changes in level across the urban fringe.
Technical location reference
Approximate map point used for Batley, United Kingdom
This coordinate is the calculation reference for Batley, United Kingdom. Extra decimal places do not make it a rooftop, property or survey point.
Coordinates and precision
- Map coordinate
- 53.703700000000000000, -1.639000000000000000
- Originally displayed coordinate
- lat53.7037 / long-1.639
How the estimate works
How this Batley estimate was calculated
Here is how I calculated the location estimate for Batley, United Kingdom.
Read how all Location estimates workSource and scope
I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.
The figures are calculated estimates, not measured output or a new NASA request while you browse.
Reference period and source details
The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.
NASA POWER project reference
The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.
This source reference does not imply NASA endorsement.
Use the result carefully
What this Batley Location estimate includes and leaves out
Use the Batley figures for broad location context, with the following boundaries in mind.
- These catalogue estimates are informational; they do not establish a site-specific production result.
- The location is an approximate reference, not a property, rooftop or survey coordinate.
- The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
- The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
- Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.