Location estimate
Petersfield
England · United Kingdom
Approximate location reference—not a rooftop, property or survey point.
Seasonal average-day estimates
Selected capacity 1 kWp
Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.
Logarithmic slider: each labelled interval is 10× capacity. Energy scales linearly with capacity.
Arrow keys change capacity by about 2.3 percent per step. Page Up and Page Down move one labelled interval. Home selects 0.1 kWp; End selects 10 MWp.
Enter exact capacity and unit
Enter at least 0.1 kWp. Decimal point or comma; no thousands separators. 1 MWp = 1,000 kWp. Changing units keeps the same capacity. Exact entry keeps your precision; slider adjustments select three-significant-figure sizes.
There is no fixed upper capacity limit. Values and results must fit the calculator’s numeric range; the slider’s range is not an exact-entry limit.
Showing seasonal average-day estimates for 1 kWp.
Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.
Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.
Summer
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Autumn
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Winter
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Spring
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Very large results use scientific notation; an approximate capacity label is marked ≈. Exact capacity and full results remain available under Source basis and scaling limits.
Shared scale: 0–6.00 kWh/day.
I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.
This is illustrative scaling, not a site-specific production prediction.
Source basis and scaling limits
Original seasonal average-day estimates for Petersfield, in kWh/kWp/day.
I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.
| Season | Recorded kWh/kWp/day | Exact selected-capacity result · kWh/day |
|---|---|---|
| Summer | 5.07 | 5.07 × 1 kWp = 5.07 kWh/day |
| Autumn | 2.25 | 2.25 × 1 kWp = 2.25 kWh/day |
| Winter | 1.03 | 1.03 × 1 kWp = 1.03 kWh/day |
| Spring | 4.28 | 4.28 × 1 kWp = 4.28 kWh/day |
Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.
Full results rounded to two decimal places
These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.
- Summer · kWh/day
- 5.07
- Autumn · kWh/day
- 2.25
- Winter · kWh/day
- 1.03
- Spring · kWh/day
- 4.28
The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.
These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.
Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.
Year-round panel setup
- Tilt from horizontal
- 43°
- Facing direction
- South
Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.
Suggested seasonal tilts
Tilt from horizontal · facing direction
- Summer
Jun, Jul, Aug - 35°South
- Autumn
Sep, Oct, Nov - 54°South
- Winter
Dec, Jan, Feb - 64°South
- Spring
Mar, Apr, May - 43°South
The seasonal electricity figures do not model gains from switching between these settings.
About this orientation
This schematic shows the year-round panel tilt and facing direction for Petersfield, England, United Kingdom.
For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.
I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.
The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.
Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.
Seasonal orientation diagrams
These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.
Summer
35° tilt · South
Illustrative direction; exact azimuth not recorded.
Autumn
54° tilt · South
Illustrative direction; exact azimuth not recorded.
Winter
64° tilt · South
Illustrative direction; exact azimuth not recorded.
Spring
43° tilt · South
Illustrative direction; exact azimuth not recorded.
View larger
Hourly electricity pattern for Petersfield, United Kingdom
Hourly profiles by season — Petersfield, United Kingdom · 2021
This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.
2021 is the method’s reference year, not verified year coverage for every point in this historical chart.
The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.
Row-spacing planning
Planning solar-panel row spacing in Petersfield
Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.
Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.
Panel and spacing inputs
Along the tilted surface, across the row. Greater than 0, up to 20 m; 2 m is an example.
Optional extra space, 0–100 m.
Starts at the recorded year-round tilt. Decimal entry is kept at your entered precision.
Linear slider: arrows select the next whole degree; Page Up/Down 10°, Home 0°, End 90°. Only moving it changes your numeric entry.
Results update automatically.
Example calculated with a 2 m panel surface length. Replace that example with the dimension of the module you are considering.
Example calculated with a 2 m panel surface length. Replace that example with the dimension of the module you are considering. Other published location estimates remain available.
Adjust the inputs to update this diagram and its results.
Row pitch including margin
≈ m
- Sunlight ray
- First row’s ground shadow
- Shadow endpoint
At this scale the panel surfaces are very small. The row labels locate them; exact dimensions remain available below.
- Calculated clear gap
- ≈ m
- Added margin
- ≈ 0 m
- Gap including margin
- ≈ m
- Panel horizontal footprint
- ≈ m
- Panel vertical rise
- ≈ m
- Pitch before margin
- ≈ m
Simplified level ground, equator-facing cross-section. Approximate Northern Hemisphere winter solstice at solar noon (day 355). The separate recorded facing direction is not an input.
One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.
Detailed inputs and unrounded results
More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.
- Panel surface length
- 2 m
- Tilt up from horizontal
- 43°
- Added margin
- 0 m
- Latitude from the catalogue
- 51.007200000000000000° (Northern Hemisphere)
- Panel horizontal footprint
- 1.462707403238341 m
- Panel vertical rise
- 1.363996720124997 m
- Calculated clear gap
- 4.904112469273054 m
- Pitch before margin
- 6.366819872511394 m
- Gap including margin
- 4.904112469273054 m
- Row pitch including margin
- 6.366819872511394 m
- Design solar elevation
- 15.543017153186353°
How this spacing estimate is calculated
I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.
δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).
Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.
The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.
The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.
Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.
Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.
Solar context for Petersfield
Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.
Petersfield's reference at 51.0072° N,0.9615° W has a strong spring and summer contribution. The town sits within the Western Rother valley amid chalk scarps and downs and Wealden greensand ridges, with woodland, streams and the Heath adding local variation to its horizons.
Read the full article
Estimated average daily output per kW of rated installed capacity is 5.07 kWh/day in summer,2.25 in autumn,1.03 in winter and 4.28 in spring. Summer leads, with spring relatively close behind. Winter is lowest, about one fifth of summer's reference, while autumn remains distinctly below spring. The system's contribution should therefore be compared with demand season by season. Long summer days and a higher solar path support the annual pattern. During winter, shorter daylight and a lower sun leave a smaller daily resource. Nearby hills, trees and buildings can further restrict the available light, so a clear summer roof does not necessarily have an equally clear winter horizon. The recorded fixed-panel reference is 43° facing South. It is a broad output-weighted setting based on simplified solar geometry. Roof pitch, support and the immediate skyline determine a feasible arrangement. These seasonal figures do not quantify an extra gain from changing tilt or from particular power electronics. The varied valley setting makes an actual shadow survey useful. A roof near a wooded rise, one among town-centre buildings and one facing broader open ground can have different clear areas. The survey should follow the sun through the day and year from the intended module positions. Passing cloud should not be treated as a loss that optimisers or micro-inverters automatically remove. Water is another local design consideration. The Rotherlands landscape includes the Rother, Tilmore Brook, springs and adjoining terrace ground. A roof layout needs clear outlets and a sound supporting structure; a ground arrangement needs measured levels, a runoff route and soil investigation appropriate to its location. Cleaning should respond to inspection, observed soiling and manufacturer guidance. Neither regular rain nor a spring pollen season establishes a universal twice-yearly professional cleaning schedule. A demand comparison using the surveyed array preserves the strong warm-season contribution while keeping winter's smaller reference in view.
Topography around Petersfield
These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.
Petersfield is a valley town within the South Downs landscape, where the Western Rother setting meets chalk scarps and downs and Wealden greensand ridges. The National Park Authority's town description places its historic centre, the Heath and views towards surrounding heights within that framework. The park is part of the town's setting, rather than a boundary reached only on moving south from it.
Read the full topography description
The Western Rother rises just north of Petersfield and flows eastwards towards its meeting with the Arun at Pulborough. That route differs from a river flowing north through the town. Its tributaries and spring-fed margins help organise the low ground and connect it with the surrounding slopes. Rotherlands provides a local example. Its management plan distinguishes a generally level part of the river floodplain from the adjoining gravel terrace occupied by playing fields. Tilmore Brook brings water through Petersfield before joining the Rother within the reserve. Springs from the terrace support wet woodland and meadows, with an old drain also carrying spring water away from the lower ground. The town's Heath and pond provide another established open-space setting. Together with wooded slopes and cultivated surroundings, these features create a mix of habitats and recreational uses rather than available solar land. Their open appearance alone does not establish low impact, easy access for construction or an electrical connection. For rooftop solar, the actual skyline of hills, trees and buildings determines the useful view towards the lower winter sun. For ground equipment, a floodplain, spring line and higher terrace call for different water and soil questions. Surveyed levels, existing drains and the local water history should guide the layout. The useful topographic framework is Petersfield's settled valley, enclosing ridges and varied water margins. It does not identify a preferred northern farmland sector or demonstrate that every former industrial site has fewer environmental constraints. A proposal needs the conditions and uses of its own property assessed directly.
Technical location reference
Approximate map point used for Petersfield, United Kingdom
This coordinate is the calculation reference for Petersfield, United Kingdom. Extra decimal places do not make it a rooftop, property or survey point.
Coordinates and precision
- Map coordinate
- 51.007200000000000000, -0.961500000000000000
- Originally displayed coordinate
- lat51.0072 / long-0.9615
How the estimate works
How this Petersfield estimate was calculated
Here is how I calculated the location estimate for Petersfield, United Kingdom.
Read how all Location estimates workSource and scope
I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.
The figures are calculated estimates, not measured output or a new NASA request while you browse.
Reference period and source details
The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.
NASA POWER project reference
The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.
This source reference does not imply NASA endorsement.
Use the result carefully
What this Petersfield Location estimate includes and leaves out
Use the Petersfield figures for broad location context, with the following boundaries in mind.
- These catalogue estimates are informational; they do not establish a site-specific production result.
- The location is an approximate reference, not a property, rooftop or survey coordinate.
- The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
- The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
- Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.