Location estimate
Guatire
Miranda · Venezuela
Approximate location reference—not a rooftop, property or survey point.
Seasonal average-day estimates
Selected capacity 1 kWp
Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.
Logarithmic slider: each labelled interval is 10× capacity. Energy scales linearly with capacity.
Arrow keys change capacity by about 2.3 percent per step. Page Up and Page Down move one labelled interval. Home selects 0.1 kWp; End selects 10 MWp.
Enter exact capacity and unit
Enter at least 0.1 kWp. Decimal point or comma; no thousands separators. 1 MWp = 1,000 kWp. Changing units keeps the same capacity. Exact entry keeps your precision; slider adjustments select three-significant-figure sizes.
There is no fixed upper capacity limit. Values and results must fit the calculator’s numeric range; the slider’s range is not an exact-entry limit.
Showing seasonal average-day estimates for 1 kWp.
Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.
Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.
Summer
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Autumn
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Winter
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Spring
kWh/day
Positive estimate rounded below 0.01 kWh/day display precision.
Very large results use scientific notation; an approximate capacity label is marked ≈. Exact capacity and full results remain available under Source basis and scaling limits.
Shared scale: 0–7.00 kWh/day.
I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.
This is illustrative scaling, not a site-specific production prediction.
Source basis and scaling limits
Original seasonal average-day estimates for Guatire, in kWh/kWp/day.
I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.
| Season | Recorded kWh/kWp/day | Exact selected-capacity result · kWh/day |
|---|---|---|
| Summer | 6.05 | 6.05 × 1 kWp = 6.05 kWh/day |
| Autumn | 6.12 | 6.12 × 1 kWp = 6.12 kWh/day |
| Winter | 5.58 | 5.58 × 1 kWp = 5.58 kWh/day |
| Spring | 6.16 | 6.16 × 1 kWp = 6.16 kWh/day |
Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.
Full results rounded to two decimal places
These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.
- Summer · kWh/day
- 6.05
- Autumn · kWh/day
- 6.12
- Winter · kWh/day
- 5.58
- Spring · kWh/day
- 6.16
The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.
These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.
Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.
Year-round panel setup
- Tilt from horizontal
- 10°
- Facing direction
- South
Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.
Suggested seasonal tilts
Tilt from horizontal · facing direction
- Summer
Jun, Jul, Aug - 5°North
- Autumn
Sep, Oct, Nov - 16°South
- Winter
Dec, Jan, Feb - 26°South
- Spring
Mar, Apr, May - 4°South
The seasonal electricity figures do not model gains from switching between these settings.
About this orientation
This schematic shows the year-round panel tilt and facing direction for Guatire, Miranda, Venezuela.
For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.
I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.
The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.
Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.
Daily tilt. Solar noon is when the Sun crosses the local meridian. Its geometric elevation at transit today is 58.2°. When the Sun is above the horizon, subtract its elevation from 90° to find the tilt from horizontal.
Local time zone: America/Caracas.
Time zone boundaries © OpenStreetMap contributors, via Timezone Boundary Builder. Request the lookup free under the ODbL.Seasonal orientation diagrams
These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.
Summer
5° tilt · North
Illustrative direction; exact azimuth not recorded.
Autumn
16° tilt · South
Illustrative direction; exact azimuth not recorded.
Winter
26° tilt · South
Illustrative direction; exact azimuth not recorded.
Spring
4° tilt · South
Illustrative direction; exact azimuth not recorded.
Today’s solar panel tilt
Today () in Guatire, Venezuela, tilt your solar panels 31.8° from horizontal, facing true south, to point them directly at the Sun at solar noon.
Local solar noon · about 12:14 -04
View larger
Hourly electricity pattern for Guatire, Venezuela
Hourly profiles by season — Guatire, Venezuela · 2021
This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.
2021 is the method’s reference year, not verified year coverage for every point in this historical chart.
The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.
Row-spacing planning
Planning solar-panel row spacing in Guatire
Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.
Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.
Panel and spacing inputs
Along the tilted surface, across the row. Greater than 0, up to 20 m; 2 m is an example.
Optional extra space, 0–100 m.
Starts at the recorded year-round tilt. Decimal entry is kept at your entered precision.
Linear slider: arrows select the next whole degree; Page Up/Down 10°, Home 0°, End 90°. Only moving it changes your numeric entry.
Results update automatically.
Example calculated with a 2 m panel surface length. Replace that example with the dimension of the module you are considering.
Example calculated with a 2 m panel surface length. Replace that example with the dimension of the module you are considering. Other published location estimates remain available.
Adjust the inputs to update this diagram and its results.
Row pitch including margin
≈ m
- Sunlight ray
- First row’s ground shadow
- Shadow endpoint
At this scale the panel surfaces are very small. The row labels locate them; exact dimensions remain available below.
- Calculated clear gap
- ≈ m
- Added margin
- ≈ 0 m
- Gap including margin
- ≈ m
- Panel horizontal footprint
- ≈ m
- Panel vertical rise
- ≈ m
- Pitch before margin
- ≈ m
Simplified level ground, equator-facing cross-section. Approximate Northern Hemisphere winter solstice at solar noon (day 355). The separate recorded facing direction is not an input.
One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.
Detailed inputs and unrounded results
More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.
- Panel surface length
- 2 m
- Tilt up from horizontal
- 10°
- Added margin
- 0 m
- Latitude from the catalogue
- 10.465900000000000000° (Northern Hemisphere)
- Panel horizontal footprint
- 1.969615506024416 m
- Panel vertical rise
- 0.34729635533386066 m
- Calculated clear gap
- 0.23351147659742016 m
- Pitch before margin
- 2.203126982621836 m
- Gap including margin
- 0.23351147659742016 m
- Row pitch including margin
- 2.203126982621836 m
- Design solar elevation
- 56.084317153186355°
How this spacing estimate is calculated
I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.
δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).
Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.
The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.
The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.
Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.
Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.
Solar context for Guatire
Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.
Guatire's recorded solar estimates are close across all four seasonal groupings. Estimated average daily generation is 6.16 kWh/day per kW of rated capacity in spring, 6.12 in autumn, 6.05 in summer and 5.58 in winter. The three highest averages are especially close. The calculation therefore shows a modest seasonal range, while individual days can still vary substantially with cloud conditions.
Read the full article
The fixed reference setting is 10 degrees facing south. It is a broad output-weighted result based on simplified solar geometry. In Guatire's valley and hill setting, the actual roof pitch and surrounding skyline need to be considered with that reference. A clear view along a valley is different from a roof facing a nearby slope or another building. Cloud reduces the direct resource and changes the balance between direct and diffuse light. Rain can remove some loose material from a module, but the shallow reference tilt does not guarantee a clean surface. Dust, leaves or other deposits should be assessed from the actual array, with monitoring helping distinguish persistent soiling from normal weather variation. Warm modules produce less power according to their temperature coefficient. Ventilation beneath an array helps limit operating temperature, while electrical enclosures and connections need the environmental protection specified for the installation. A tropical label alone does not establish accelerated degradation or justify adding a protective coating to components without the manufacturer's guidance. The local water setting also matters. Guatire and Pacairigua are named river corridors within the developed municipality, so roof runoff and ground-level equipment need to be related to the site's drainage rather than only to its sunlight. A building above one channel and a lower surface beside another can have similar regional solar estimates yet different physical requirements. The modest seasonal spread can be useful for recurring daytime demand. It does not guarantee uninterrupted supply or a return on investment. Night-time use and longer cloudy periods need a separate energy balance, allowing for storage losses and the actual system layout. The reference values provide the comparative resource while the local property determines how much of it an array can use.
Topography around Guatire
These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.
Guatire lies in Miranda's developed valley country east of Caracas, within the Cordillera de la Costa setting. The Guatire and Pacairigua river corridors give the town its immediate hydrological frame. Calling it simply a town on the Tuy valley floor misses those nearer valleys and the relationship between the settlement and surrounding hills.
Read the full topography description
Zamora's municipal account identifies the Guatire River at El Ingenio and the Pacairigua at La Churca in Valle Arriba, alongside the municipality's residential, commercial and industrial areas. The rivers are therefore part of a working urban landscape, with neighbourhoods and activity extending around them. Historical geographic reporting also connects the Guatire and Pacairigua downstream within the Caucagua drainage, rather than placing the Tuy itself through the town. The contrast between lower river corridors and rising ground creates different local horizons. A surface beside a channel may look along an open valley while facing a closer obstruction across it. A roof on higher ground may see over nearby development in one direction and toward a hillside in another. The general appearance of gentle terrain cannot establish unrestricted sunlight throughout the day. Water pathways are equally local. Runoff from the surrounding slopes and developed surfaces must pass through channels and lower ground. A raised terrace may change that relationship without proving good drainage or easy foundations. A broad-looking surface can retain small depressions, banks and cut slopes that matter to equipment placement and access. The urban valley also has established land uses. Commercial or industrial roof area needs to be assessed with its structural support, roof equipment and neighbouring buildings. Open land between developed areas is not automatically available for an array, and land farther toward Caucagua belongs to a wider landscape requiring its own assessment. Guatire's useful solar context is the interplay of river corridors, built neighbourhoods and surrounding hills. It gives a more concrete basis for examining a roof or ground surface than ranking southern and southeastern plains, presumed western parcels or every northern slope as preferred or unsuitable development land.
Technical location reference
Approximate map point used for Guatire, Venezuela
This coordinate is the calculation reference for Guatire, Venezuela. Extra decimal places do not make it a rooftop, property or survey point.
Coordinates and precision
- Map coordinate
- 10.465900000000000000, -66.546000000000000000
- Originally displayed coordinate
- lat10.4659 / long-66.546
How the estimate works
How this Guatire estimate was calculated
Here is how I calculated the location estimate for Guatire, Venezuela.
Read how all Location estimates workSource and scope
I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.
The figures are calculated estimates, not measured output or a new NASA request while you browse.
Reference period and source details
The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.
NASA POWER project reference
The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.
This source reference does not imply NASA endorsement.
Use the result carefully
What this Guatire Location estimate includes and leaves out
Use the Guatire figures for broad location context, with the following boundaries in mind.
- These catalogue estimates are informational; they do not establish a site-specific production result.
- The location is an approximate reference, not a property, rooftop or survey coordinate.
- The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
- The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
- Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.