Location estimate

Rūpnagar

Rajasthan · India

Approximate location reference—not a rooftop, property or survey point.

Seasonal average-day estimates

Selected capacity 1 kWp

Showing the original estimates at 1 kWp. JavaScript is needed only to change capacity; source values and panel settings remain available below.

Changing capacity rescales my existing estimates. It does not recalculate their orientation, shading, equipment or loss assumptions.

Estimated average daily electricity for 1 kWp, in kWh/day, averaged over each season.

Summer

5.69

kWh/day

Autumn

4.97

kWh/day

Winter

4.60

kWh/day

Spring

7.18

kWh/day

Shared scale: 0–8.00 kWh/day.

I apply the same capacity factor to every season, so their proportions stay unchanged. The shared visual scale adjusts with capacity. To compare different system sizes, use the displayed kWh/day values.

This is illustrative scaling, not a site-specific production prediction.

Source basis and scaling limits

Original seasonal average-day estimates for Rūpnagar, in kWh/kWp/day.

I calculate the scaled results from the original seasonal values and round the final energy results to two decimal places. Exceptionally large values may appear in approximate scientific notation; the full results, rounded to two decimal places, remain available here.

Original source values and selected-capacity calculation
SeasonRecorded kWh/kWp/dayExact selected-capacity result · kWh/day
Summer 5.69 5.69 × 1 kWp = 5.69 kWh/day
Autumn 4.97 4.97 × 1 kWp = 4.97 kWh/day
Winter 4.60 4.60 × 1 kWp = 4.60 kWh/day
Spring 7.18 7.18 × 1 kWp = 7.18 kWh/day

Ordinary calculations wrap onto two lines. Exceptionally long calculations can be scrolled within their labelled region.

Full results rounded to two decimal places

These preserve every whole-number digit. Exceptionally long values can be scrolled horizontally inside each labelled result.

Summer · kWh/day
5.69
Autumn · kWh/day
4.97
Winter · kWh/day
4.60
Spring · kWh/day
7.18

The original values remain available without JavaScript. Energy always uses kWh/day, including when capacity is entered in MWp. Changing units preserves the same physical capacity.

These are seasonal average-day estimates, not annual totals or installation sizing. Changing capacity does not revisit the assumptions used in my original estimates.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Year-round panel setup

Schematic catalogue setting — Year-round fixed panel setup: tilt 23 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Year-round fixed panel setup · schematic
Tilt from horizontal
23°
Facing direction
South

Catalogue direction; exact azimuth not recorded. The facing direction is illustrative.

Suggested seasonal tilts

Tilt from horizontal · facing direction

Summer
Jun, Jul, Aug
9°South
Autumn
Sep, Oct, Nov
31°South
Winter
Dec, Jan, Feb
40°South
Spring
Mar, Apr, May
19°South

The seasonal electricity figures do not model gains from switching between these settings.

About this orientation

This schematic shows the year-round panel tilt and facing direction for Rūpnagar, Rajasthan, India.

For the year-round panel tilt, I used a simplified solar-noon calculation. This gives a broad starting point for considering a fixed panel angle at the location.

I weighted the daily angles by their share of estimated output. Read how I calculated panel tilt.

The panel shows tilt above horizontal on a fixed compass. North stays at the upper right in this projected view. Schematic only—not roof geometry, an installation drawing or a selected practical design.

Year-round and seasonal panel angles are separate estimates. Changing capacity rescales the existing energy values; it does not recalculate output for a different angle or facing direction.

Seasonal orientation diagrams

These show the separate seasonal settings above. Changing capacity does not change these angles or recalculate energy for a different orientation.

Summer

Schematic catalogue setting — Summer panel setup: tilt 9 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Summer panel setup · schematic

9° tilt · South

Illustrative direction; exact azimuth not recorded.

Autumn

Schematic catalogue setting — Autumn panel setup: tilt 31 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Autumn panel setup · schematic

31° tilt · South

Illustrative direction; exact azimuth not recorded.

Winter

Schematic catalogue setting — Winter panel setup: tilt 40 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Winter panel setup · schematic

40° tilt · South

Illustrative direction; exact azimuth not recorded.

Spring

Schematic catalogue setting — Spring panel setup: tilt 19 degrees above horizontal; facing South. Direction is illustrative; exact azimuth not recorded.NESW
Spring panel setup · schematic

19° tilt · South

Illustrative direction; exact azimuth not recorded.

Historical hourly-by-season solar output chart for Rūpnagar, India. View larger
Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

Hourly electricity pattern for Rūpnagar, India

Hourly profiles by season — Rūpnagar, India · 2021

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

2021 is the method’s reference year, not verified year coverage for every point in this historical chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern. View the year-round panel setup.

Historical hourly chart

Hourly profiles by season — Rūpnagar, India · 2021

Swipe to pan, or focus the chart and use arrow keys.

Original chart units: hourly average electricity output in kWh per kW of installed solar PV.

This chart shows how average electricity output varies through the hours of the day in each season. I have kept its original per-capacity basis: changing the capacity slider does not change this chart.

The cards above show seasonal average-day energy; this chart shows the hourly pattern.

2021 is the method’s reference year, not verified year coverage for every plotted point.

Enlargement is limited to the original image resolution.

Row-spacing planning

Planning solar-panel row spacing in Rūpnagar

Explore the space between parallel panel rows at one assumed winter-solstice solar-noon position.

Example: 2 m panel surface length, recorded year-round tilt and no added margin. Enable JavaScript to change these inputs.

Row pitch including margin

≈ 2.73 m

Proportional side viewDesign sun: ≈ 41.19° above horizontal
Row 1 Row 2 Clear gap Added margin: 0 m Row pitch including margin
  • Sunlight ray
  • First row’s ground shadow
  • Shadow endpoint
Calculated clear gap
≈ 0.89 m
Added margin
≈ 0 m
Gap including margin
≈ 0.89 m
Panel horizontal footprint
≈ 1.84 m
Panel vertical rise
≈ 0.78 m
Pitch before margin
≈ 2.73 m

Simplified level ground, equator-facing cross-section. Approximate Northern Hemisphere winter solstice at solar noon (day 355). The separate recorded facing direction is not an input.

One sun position, not a complete site-shading assessment. A geometric zero gap does not establish adequate installation, access or maintenance clearance.

Detailed inputs and unrounded results

More digits retain calculation precision; they do not imply greater model accuracy. Pitch including margin is pitch before margin plus the added margin, including when that margin is zero.

Panel surface length
2 m
Tilt up from horizontal
23°
Added margin
0 m
Latitude from the catalogue
25.360600000000000000° (Northern Hemisphere)
Panel horizontal footprint
1.8410097069048807 m
Panel vertical rise
0.7814622569785474 m
Calculated clear gap
0.8929836052157702 m
Pitch before margin
2.733993312120651 m
Gap including margin
0.8929836052157702 m
Row pitch including margin
2.733993312120651 m
Design solar elevation
41.18961715318636°
How this spacing estimate is calculated

I calculate this example at approximate winter solstice and solar noon for the location’s hemisphere. Tilt is measured up from horizontal and panel length is measured along the tilted module surface.

δ = 23.45° × sin(360° × (day − 81) ÷ 365); α = asin(sin(latitude) × sin(δ) + cos(latitude) × cos(δ)).

Rise = length × sin(tilt). Footprint = length × cos(tilt). Clear gap = rise ÷ tan(α). Row pitch = footprint + clear gap. The optional margin is added to the gap and pitch.

The calculated clear gap is the horizontal distance from the first panel’s high edge to its shadow endpoint. Any added margin then extends to the next row. Pitch is measured between corresponding leading edges, not just across the clear gap. The target is no geometric shadow at that one simplified solar-noon design instant.

The cross-section assumes parallel, equator-facing rows and a solar-noon ray perpendicular to them. The method ignores azimuth error and does not use the separate facing direction recorded for this location.

Terrain, mounting height, module thickness, obstructions, structural loads and regulations are outside this simplified geometry. A qualified designer should verify a real installation.

Detailed site analysisExplore historical generation and system configurations for your own project or your clients in the profileSOLAR app.

Solar context for Rūpnagar

Read this location context alongside the calculation method and limitations; installation guidance is not a site-specific assessment.

Rūpnagar’s wider setting in the Bundi area of Rajasthan includes plains, isolated mounds and the Vindhyan hill ranges. This changing relief gives the local horizon more variety than a uniformly level agricultural plain. It is useful context when comparing a roof within a settlement with ground beside higher land.

Read the full article

Our seasonal estimates peak in spring at 7.18 kWh/day per kW of rated capacity. Summer follows at 5.69, autumn at 4.97 and winter at 4.60 kWh/day per kW. These are estimated average daily electricity yields for each season. Spring’s lead is substantial, while the difference between autumn and winter is much smaller; the figures support generation across the year with a clear spring maximum. The fixed reference is a tilt of 23 degrees facing South. We derive this broad annual reference from simplified solar geometry weighted by the available solar resource. A roof’s actual pitch and its view past nearby trees, buildings or relief determine how closely a practical arrangement can follow it. The Bundi landscape also has a connected drainage system, with the Mej catchment covering much of the district and feeding the Chambal. For a ground installation, following the actual fall of the land and keeping runoff routes clear is a useful starting point. For a roof, a clear solar window matters more than whether the surrounding countryside appears open. Cleaning can respond to observed deposits and changes in performance, with access designed into the installation.

Topography around Rūpnagar

These landscape descriptions provide general context. The calculations do not model terrain, obstructions, shading or property suitability.

Rūpnagar is considered here in its wider Bundi-area setting in Rajasthan. The district’s terrain ranges from level ground to undulating country with isolated mounds. A Vindhyan range trends northeast to southwest through it, separating areas with different overall drainage gradients.

Read the full topography description

The regional landforms include rocky pediments, structural plains, alluvial ground and ravines. Alluvial plains occur between the Chambal and Mej rivers in the southeast of the district, while erosion has cut ravines in parts of that river landscape. These are distinct settings within the wider area, rather than a single soil or landform that can be assigned to every village or property. The Mej and its tributaries drain much of Bundi toward the Chambal along the district’s southeastern edge. Local hollows and channels therefore deserve attention even where the ground looks gently sloping. Keeping their flow paths continuous helps a layout fit the existing landscape. For solar planning, the useful distinction is between the distant hill horizon and close obstructions around the proposed array. A low ridge can shorten the visible solar window, while a nearby tree or building can shade only part of a roof. On ground sites, slope breaks and drainage lines shape row placement and access. The description of the wider plains does not establish an available development parcel.

Technical location reference

Approximate map point used for Rūpnagar, India

This coordinate is the calculation reference for Rūpnagar, India. Extra decimal places do not make it a rooftop, property or survey point.

Coordinates and precision
Map coordinate
25.360600000000000000, 75.550200000000000000
Originally displayed coordinate
lat25.3606 / long75.5502

How the estimate works

How this Rūpnagar estimate was calculated

Here is how I calculated the location estimate for Rūpnagar, India.

Read how all Location estimates work

Source and scope

I calculated these location estimates using hourly NASA POWER solar-resource data, with 2021 as the reference year. The seasonal figures show estimated daily electricity production averaged over each season, on a common panel-capacity basis.

The figures are calculated estimates, not measured output or a new NASA request while you browse.

Reference period and source details

The reference year describes the intended input period; complete source-year coverage is not established for every historical result. Read the technical questions about source data and downloads.

NASA POWER project reference

The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division.

This source reference does not imply NASA endorsement.

Use the result carefully

What this Rūpnagar Location estimate includes and leaves out

Use the Rūpnagar figures for broad location context, with the following boundaries in mind.

  • These catalogue estimates are informational; they do not establish a site-specific production result.
  • The location is an approximate reference, not a property, rooftop or survey coordinate.
  • The energy figures support broad location comparisons; they are not a generation guarantee or detailed system design.
  • The seasonal cards show average-day energy. An hourly chart, where available, shows a different view of the daily pattern.
  • Distance and clearance between rows require panel dimensions, mounting height, terrain, acceptable shading and a project-specific design.

Keep exploring

Compare Rūpnagar with another location

Back to country results

Detailed site analysis

Take it a step further

Whether you’re exploring solar for your own project or comparing options for your clients, profileSOLAR helps you assess historical generation, compare system configurations and produce clear reports.

Detailed analysis for your project or your clients.

Explore features and paid access in the app, or use the complimentary testing access included in your invitation.

Analysis features and access

The profileSOLAR app supports hourly solar analysis over periods of up to five consecutive years, subject to available source data. No electricity-use file is required for this solar analysis.

Compare supported panel configurations, then download Summary or Detailed PDF reports for the saved Analysis.

Testing access includes only the features and allowances stated in your invitation. Your catalogue selection is not transferred; choose your exact site in the app.

Explore detailed site analysis